"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2024-37993",
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "siemens",
|
|
"dateReserved": "2024-06-11T08:32:52.184Z",
|
|
"datePublished": "2024-09-10T09:36:39.074Z",
|
|
"dateUpdated": "2024-09-10T15:04:32.084Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens",
|
|
"dateUpdated": "2024-09-10T09:36:39.074Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF610R CMIIT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF610R ETSI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF610R FCC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF615R CMIIT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF615R ETSI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF615R FCC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF650R ARIB",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF650R CMIIT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF650R ETSI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF650R FCC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF680R ARIB",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF680R CMIIT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF680R ETSI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF680R FCC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF685R ARIB",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF685R CMIIT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF685R ETSI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Reader RF685R FCC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF1140R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF1170R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF166C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF185C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF186C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF186CI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF188C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF188CI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF360R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
},
|
|
{
|
|
"cvssV4_0": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
|
|
"baseScore": 6.9,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-284",
|
|
"description": "CWE-284: Improper Access Control",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html"
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-09-10T15:04:12.477171Z",
|
|
"id": "CVE-2024-37993",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-09-10T15:04:32.084Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |