Files
vuln-cve/data/2024/37xxx/CVE-2024-37367.json
T

181 lines
8.6 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-37367",
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"state": "PUBLISHED",
"assignerShortName": "Rockwell",
"dateReserved": "2024-06-06T20:18:27.551Z",
"datePublished": "2024-06-14T14:17:54.951Z",
"dateUpdated": "2024-08-02T03:50:56.151Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk® View SE",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "v12"
}
]
}
],
"datePublic": "2024-06-13T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.</span>\n\n"
}
],
"value": "A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell",
"dateUpdated": "2024-06-14T14:17:54.951Z"
},
"references": [
{
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<ul><li>Corrected in software version v14.0. </li><li><p>Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.   </p><ul><li><p>It is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\">https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456</a></p></li></ul><ul><li><p><a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">Security Best Practices</a></p></li></ul></li></ul>\n\n<br>"
}
],
"value": "* Corrected in software version v14.0. \n * Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.   \n\n * It is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456 \n\n\n\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk® View SE v12 Information Leakage Vulnerability via Authentication Restriction",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-06-17T15:37:14.017276Z",
"id": "CVE-2024-37367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-17T15:37:26.533Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T03:50:56.151Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html",
"tags": [
"x_transferred"
]
}
]
}
]
}
}