Files
vuln-cve/data/2024/36xxx/CVE-2024-36389.json
T

174 lines
6.7 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-36389",
"assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"state": "PUBLISHED",
"assignerShortName": "INCD",
"dateReserved": "2024-05-27T13:04:44.110Z",
"datePublished": "2024-06-02T13:21:11.748Z",
"dateUpdated": "2024-08-02T03:37:04.960Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DeviceHub",
"vendor": "MileSight",
"versions": [
{
"lessThan": "Upgrade to the latest version.",
"status": "affected",
"version": "v3.0.1-r1 for Ubuntu 20.04",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Claroty Research – Team 82"
}
],
"datePublic": "2024-06-02T13:10:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<p>MileSight DeviceHub - <span style=\"background-color: rgb(255, 255, 255);\"><span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">CWE-330 Use of Insufficiently Random Values may allow Authentication Bypass</span>\n\n</span>\n\n</span>\n\n</span>\n\n</span>\n\n</p><br>\n\n"
}
],
"value": "MileSight DeviceHub - \n\n\n\n\n\nCWE-330 Use of Insufficiently Random Values may allow Authentication Bypass"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330 Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"shortName": "INCD",
"dateUpdated": "2024-06-02T13:21:11.748Z"
},
"references": [
{
"url": "https://www.gov.il/en/Departments/faq/cve_advisories"
}
],
"source": {
"advisory": "ILVN-2024-0158",
"discovery": "UNKNOWN"
},
"title": "MileSight DeviceHub - CWE-330 Use of Insufficiently Random Values",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"affected": [
{
"vendor": "milesight",
"product": "devicehub",
"cpes": [
"cpe:2.3:a:milesight:devicehub:3.0.1-r1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "3.0.1-r1",
"status": "affected"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-06-03T15:47:51.777014Z",
"id": "CVE-2024-36389",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-07-23T16:24:23.066Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T03:37:04.960Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.gov.il/en/Departments/faq/cve_advisories",
"tags": [
"x_transferred"
]
}
]
}
]
}
}