Files
vuln-cve/data/2024/31xxx/CVE-2024-31146.json
T

166 lines
7.1 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-31146",
"assignerOrgId": "23aa2041-22e1-471f-9209-9b7396fa234f",
"state": "PUBLISHED",
"assignerShortName": "XEN",
"dateReserved": "2024-03-28T18:14:12.893Z",
"datePublished": "2024-09-25T10:31:51.154Z",
"dateUpdated": "2024-09-25T13:24:47.409Z"
},
"containers": {
"cna": {
"title": "PCI device pass-through with shared resources",
"datePublic": "2024-08-13T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "When multiple devices share resources and one of them is to be passed\nthrough to a guest, security of the entire system and of respective\nguests individually cannot really be guaranteed without knowing\ninternals of any of the involved guests. Therefore such a configuration\ncannot really be security-supported, yet making that explicit was so far\nmissing.\n\nResources the sharing of which is known to be problematic include, but\nare not limited to\n- - PCI Base Address Registers (BARs) of multiple devices mapping to the\n same page (4k on x86),\n- - INTx lines."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "The precise effects when shared resources are in use are system, device,\nguest, and resource specific. None of privilege escalation, information\nleaks, or Denial of Service (DoS) can be ruled out."
}
]
}
],
"affected": [
{
"defaultStatus": "unknown",
"product": "Xen",
"vendor": "Xen",
"versions": [
{
"status": "unknown",
"version": "consult Xen advisory XSA-461"
}
]
}
],
"configurations": [
{
"lang": "en",
"value": "All systems making use of PCI pass-through are in principle vulnerable,\nwhen any kind of resource is shared. Just to re-iterate, even in the\nabsence of resource sharing caveats apply to passing through of PCI\ndevices to entirely untrusted guests."
}
],
"workarounds": [
{
"lang": "en",
"value": "Passing through only SR-IOV virtual functions or devices with well-\nseparated resources will avoid this particular vulnerability. Passing\nthrough all devices sharing a given resource to the same guest will also\navoid this particular vulnerability."
}
],
"references": [
{
"url": "https://xenbits.xenproject.org/xsa/advisory-461.html"
}
],
"providerMetadata": {
"orgId": "23aa2041-22e1-471f-9209-9b7396fa234f",
"shortName": "XEN",
"dateUpdated": "2024-09-25T10:31:51.154Z"
}
},
"adp": [
{
"title": "CVE Program Container",
"references": [
{
"url": "http://xenbits.xen.org/xsa/advisory-461.html"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/08/14/3"
}
],
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-09-25T11:02:55.207Z"
}
},
{
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-400",
"lang": "en",
"description": "CWE-400 Uncontrolled Resource Consumption"
}
]
}
],
"affected": [
{
"vendor": "xen",
"product": "xen",
"cpes": [
"cpe:2.3:o:xen:xen:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "0",
"status": "affected",
"lessThanOrEqual": "*",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
}
},
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-09-25T13:14:46.996097Z",
"id": "CVE-2024-31146",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-09-25T13:24:47.409Z"
}
}
]
}
}