150 lines
5.6 KiB
JSON
150 lines
5.6 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"state": "PUBLISHED",
|
|
"cveId": "CVE-2024-30613",
|
|
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"assignerShortName": "mitre",
|
|
"dateUpdated": "2024-08-02T01:39:00.913Z",
|
|
"dateReserved": "2024-03-27T00:00:00.000Z",
|
|
"datePublished": "2024-03-29T00:00:00.000Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"shortName": "mitre",
|
|
"dateUpdated": "2024-03-29T12:23:00.930Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Tenda AC15 v15.03.05.18 has a stack overflow vulnerability in the time parameter from the setSmartPowerManagement function."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "n/a",
|
|
"product": "n/a",
|
|
"versions": [
|
|
{
|
|
"version": "n/a",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/setSmartPowerManagement.md"
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "text",
|
|
"lang": "en",
|
|
"description": "n/a"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-787",
|
|
"lang": "en",
|
|
"description": "CWE-787 Out-of-bounds Write"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "tenda",
|
|
"product": "ac15_firmware",
|
|
"cpes": [
|
|
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
|
|
],
|
|
"defaultStatus": "unknown",
|
|
"versions": [
|
|
{
|
|
"version": "15.03.05.18",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"scope": "UNCHANGED",
|
|
"version": "3.1",
|
|
"baseScore": 4.3,
|
|
"attackVector": "NETWORK",
|
|
"baseSeverity": "MEDIUM",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
|
|
"integrityImpact": "LOW",
|
|
"userInteraction": "NONE",
|
|
"attackComplexity": "LOW",
|
|
"availabilityImpact": "NONE",
|
|
"privilegesRequired": "LOW",
|
|
"confidentialityImpact": "NONE"
|
|
}
|
|
},
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-03-29T15:04:34.024167Z",
|
|
"id": "CVE-2024-30613",
|
|
"options": [
|
|
{
|
|
"Exploitation": "poc"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-08-01T14:44:53.439Z"
|
|
}
|
|
},
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-02T01:39:00.913Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/setSmartPowerManagement.md",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |