Files
vuln-cve/data/2024/27xxx/CVE-2024-27767.json
T

189 lines
7.1 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-27767",
"assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"state": "PUBLISHED",
"assignerShortName": "INCD",
"dateReserved": "2024-02-26T09:27:55.322Z",
"datePublished": "2024-03-18T13:13:36.868Z",
"dateUpdated": "2024-08-02T00:41:54.434Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unistream Unilogic",
"vendor": "Unitronics ",
"versions": [
{
"lessThan": "1.35.227",
"status": "affected",
"version": "All versions",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Noam Moshe, Vera Mens of Claroty Team82"
}
],
"datePublic": "2024-03-18T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">CWE-287: Improper Authentication may allow Authentication Bypass</span>\n\n"
}
],
"value": "\nCWE-287: Improper Authentication may allow Authentication Bypass\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"shortName": "INCD",
"dateUpdated": "2024-03-18T13:13:36.868Z"
},
"references": [
{
"url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Upgrade to version 1.35.227 or later.</span>\n\n<br>"
}
],
"value": "\nUpgrade to version 1.35.227 or later.\n\n"
}
],
"source": {
"advisory": "ILVN-2024-0147",
"discovery": "UNKNOWN"
},
"title": "Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-287: Improper Authentication",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"affected": [
{
"vendor": "unitronics",
"product": "unistream_unilogic",
"cpes": [
"cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "0",
"status": "affected",
"lessThan": "1.35.227",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-03-18T18:22:57.969128Z",
"id": "CVE-2024-27767",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-20T21:26:31.866Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T00:41:54.434Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0",
"tags": [
"x_transferred"
]
}
]
}
]
}
}