"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-10654",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"state": "PUBLISHED",
"assignerShortName": "VulDB",
"dateReserved": "2024-11-01T05:59:04.960Z",
"datePublished": "2024-11-01T11:31:05.723Z",
"dateUpdated": "2024-11-05T07:04:37.847Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2024-11-05T07:04:37.847Z"
},
"title": "TOTOLINK LR350 formLoginAuth.htm authorization",
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-639",
"lang": "en",
"description": "Authorization Bypass"
}
]
},
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-285",
"lang": "en",
"description": "Improper Authorization"
}
]
},
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-266",
"lang": "en",
"description": "Incorrect Privilege Assignment"
}
]
}
],
"affected": [
{
"vendor": "TOTOLINK",
"product": "LR350",
"versions": [
{
"version": "9.3.5u.6369",
"status": "affected"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in TOTOLINK LR350 up to 9.3.5u.6369 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /formLoginAuth.htm. The manipulation of the argument authCode with the input 1 leads to authorization bypass. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 9.3.5u.6698_B20230810 is able to address this issue. It is recommended to upgrade the affected component."
},
{
"lang": "de",
"value": "In TOTOLINK LR350 bis 9.3.5u.6369 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Betroffen ist eine unbekannte Verarbeitung der Datei /formLoginAuth.htm. Dank der Manipulation des Arguments authCode mit der Eingabe 1 mit unbekannten Daten kann eine authorization bypass-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk passieren. Der Exploit steht zur öffentlichen Verfügung. Ein Aktualisieren auf die Version 9.3.5u.6698_B20230810 vermag dieses Problem zu lösen. Als bestmögliche Massnahme wird das Einspielen eines Upgrades empfohlen."
}
],
"metrics": [
{
"cvssV4_0": {
"version": "4.0",
"baseScore": 6.9,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"baseSeverity": "MEDIUM"
}
},
{
"cvssV3_1": {
"version": "3.1",
"baseScore": 5.3,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"baseSeverity": "MEDIUM"
}
},
{
"cvssV3_0": {
"version": "3.0",
"baseScore": 5.3,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"baseSeverity": "MEDIUM"
}
},
{
"cvssV2_0": {
"version": "2.0",
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N"
}
}
],
"timeline": [
{
"time": "2023-09-07T00:00:00.000Z",
"lang": "en",
"value": "Countermeasure disclosed"
},
{
"time": "2024-11-01T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2024-11-01T01:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2024-11-05T08:09:26.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "c0nyy (VulDB User)",
"type": "reporter"
},
{
"lang": "en",
"value": "c0nyy (VulDB User)",
"type": "analyst"
}
],
"references": [
{
"url": "https://vuldb.com/?id.282667",
"name": "VDB-282667 | TOTOLINK LR350 formLoginAuth.htm authorization",
"tags": [
"vdb-entry",
"technical-description"
]
},
{
"url": "https://vuldb.com/?ctiid.282667",
"name": "VDB-282667 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/?submit.434801",
"name": "Submit #434801 | TOTOLINK LR350 V9.3.5u.6369 Authorization Bypass",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://github.com/c0nyy/IoT_vuln/blob/main/TOTOLINK%20LR350%20Vuln.md",
"tags": [
"exploit"
]
},
{
"url": "https://www.totolink.net/home/menu/detail/menu_listtpl/download/id/231/ids/36.html",
"tags": [
"patch"
]
},
{
"url": "https://www.totolink.net/",
"tags": [
"product"
]
}
]
},
"adp": [
{
"affected": [
{
"vendor": "totolink",
"product": "lr350",
"cpes": [
"cpe:2.3:h:totolink:lr350:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "9.3.5u.6369",
"status": "affected"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-11-01T13:24:06.276632Z",
"id": "CVE-2024-10654",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-11-01T13:24:57.992Z"
}
}
]
}
}