Files
vuln-cve/data/2024/10xxx/CVE-2024-10386.json
T

284 lines
14 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-10386",
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"state": "PUBLISHED",
"assignerShortName": "Rockwell",
"dateReserved": "2024-10-25T12:38:28.748Z",
"datePublished": "2024-10-25T17:04:34.000Z",
"dateUpdated": "2024-10-25T20:17:55.566Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk ThinManager",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "11.2.0-11.2.9"
},
{
"status": "affected",
"version": "12.0.0-12.0.7"
},
{
"status": "affected",
"version": "12.1.0-12.1.8"
},
{
"status": "affected",
"version": "13.0.0-13.0.5"
},
{
"status": "affected",
"version": "13.1.0-13.1.3"
},
{
"status": "affected",
"version": "13.2.0-13.2.2"
},
{
"status": "affected",
"version": "14.0.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tenable Network Security"
}
],
"datePublic": "2024-10-25T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<p><b><u>CVE-2024-10386 IMPACT</u></b><u></u></p>\n\n<p>An authentication\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device, potentially\nresulting in database manipulation.</p>"
}
],
"value": "CVE-2024-10386 IMPACT\n\n\n\nAn authentication\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device, potentially\nresulting in database manipulation."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell",
"dateUpdated": "2024-10-25T17:04:34.000Z"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<span style=\"background-color: var(--wht);\">· &nbsp; &nbsp; &nbsp; &nbsp;\nIf able,\nnavigate to the </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\">ThinManager® download site</a><span style=\"background-color: var(--wht);\"> and upgrade to a corrected version of ThinManager®</span>\n\n<br><br><p>11.2.10<br>\n</p>\n\n<p>12.0.8<br>\n</p>\n\n<p>12.1.9<br>\n</p>\n\n<p>13.0.6&nbsp;</p>\n\n\n\n<p>13.1.4&nbsp;</p>\n\n\n\n<p>13.2.3&nbsp;</p>\n\n\n\n<p>14.0.1</p>\n\n\n\n\n\n<br>"
}
],
"value": "·        \nIf able,\nnavigate to the ThinManager® download site https://thinmanager.com/downloads/ and upgrade to a corrected version of ThinManager®\n\n\n\n11.2.10\n\n\n\n\n\n12.0.8\n\n\n\n\n\n12.1.9\n\n\n\n\n\n13.0.6 \n\n\n\n\n\n13.1.4 \n\n\n\n\n\n13.2.3 \n\n\n\n\n\n14.0.1"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation FactoryTalk ThinManager Authentication Vulnerability",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<p><span style=\"background-color: var(--wht);\">· &nbsp; &nbsp; &nbsp; &nbsp;\nIf able,\nnavigate to the </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\">ThinManager® download site</a><span style=\"background-color: var(--wht);\"> and upgrade to a corrected version of ThinManager®</span></p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nImplement\nnetwork hardening for ThinManager® Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager®</p>\n\n<p>· &nbsp; &nbsp; &nbsp; &nbsp;\nFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">security best\npractices</a> to\nminimize the risk of the vulnerability.</p>\n\n\n\n\n\n<br>"
}
],
"value": "·        \nIf able,\nnavigate to the ThinManager® download site https://thinmanager.com/downloads/ and upgrade to a corrected version of ThinManager®\n\n\n\n·        \nImplement\nnetwork hardening for ThinManager® Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager®\n\n\n\n·        \nFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested security best\npractices to\nminimize the risk of the vulnerability."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"affected": [
{
"vendor": "rockwellautomation",
"product": "thinmanager",
"cpes": [
"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"versions": [
{
"version": "11.2.0",
"status": "affected",
"lessThanOrEqual": "11.2.9",
"versionType": "custom"
},
{
"version": "12.0.0",
"status": "affected",
"lessThanOrEqual": "12.0.7",
"versionType": "custom"
},
{
"version": "12.1.0",
"status": "affected",
"lessThanOrEqual": "12.1.8",
"versionType": "custom"
},
{
"version": "13.0.0",
"status": "affected",
"lessThanOrEqual": "13.0.5",
"versionType": "custom"
},
{
"version": "13.1.0",
"status": "affected",
"lessThanOrEqual": "13.1.3",
"versionType": "custom"
},
{
"version": "13.2.0",
"status": "affected",
"lessThanOrEqual": "13.2.2",
"versionType": "custom"
},
{
"version": "14.0.0",
"status": "affected"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-10-25T20:14:39.256573Z",
"id": "CVE-2024-10386",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-10-25T20:17:55.566Z"
}
}
]
}
}