250 lines
10 KiB
JSON
250 lines
10 KiB
JSON
{
|
||
"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.1",
|
||
"cveMetadata": {
|
||
"cveId": "CVE-2024-0154",
|
||
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
|
||
"state": "PUBLISHED",
|
||
"assignerShortName": "dell",
|
||
"dateReserved": "2023-12-14T05:29:25.760Z",
|
||
"datePublished": "2024-03-13T16:41:09.360Z",
|
||
"dateUpdated": "2024-08-01T17:41:16.006Z"
|
||
},
|
||
"containers": {
|
||
"cna": {
|
||
"affected": [
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "PowerEdge Platform",
|
||
"vendor": "Dell",
|
||
"versions": [
|
||
{
|
||
"lessThan": "2.0.0",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "1.7.6",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "1.7.2",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "1.2.3",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "1.13.2",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "1.14.1",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "1.9.1",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.14.1",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.21.2",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.21.1",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.21.0",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.16.0",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.19.0 ",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.14.0 ",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "1.19.0 ",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
},
|
||
{
|
||
"lessThan": "2.20.0 ",
|
||
"status": "affected",
|
||
"version": "N/A",
|
||
"versionType": "semver"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"type": "finder",
|
||
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
|
||
}
|
||
],
|
||
"datePublic": "2024-03-12T06:30:00.000Z",
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
|
||
}
|
||
],
|
||
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV3_1": {
|
||
"attackComplexity": "LOW",
|
||
"attackVector": "LOCAL",
|
||
"availabilityImpact": "NONE",
|
||
"baseScore": 3.8,
|
||
"baseSeverity": "LOW",
|
||
"confidentialityImpact": "LOW",
|
||
"integrityImpact": "NONE",
|
||
"privilegesRequired": "LOW",
|
||
"scope": "CHANGED",
|
||
"userInteraction": "NONE",
|
||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
|
||
"version": "3.1"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-788",
|
||
"description": "CWE-788: Access of Memory Location After End of Buffer",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
|
||
"shortName": "dell",
|
||
"dateUpdated": "2024-03-13T16:41:09.360Z"
|
||
},
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"vendor-advisory"
|
||
],
|
||
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
|
||
}
|
||
],
|
||
"source": {
|
||
"discovery": "UNKNOWN"
|
||
},
|
||
"x_generator": {
|
||
"engine": "Vulnogram 0.1.0-dev"
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"title": "CISA ADP Vulnrichment",
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"id": "CVE-2024-0154",
|
||
"role": "CISA Coordinator",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "no"
|
||
},
|
||
{
|
||
"Technical Impact": "partial"
|
||
}
|
||
],
|
||
"version": "2.0.3",
|
||
"timestamp": "2024-03-13T19:40:48.987776Z"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2024-06-04T17:58:45.175Z"
|
||
}
|
||
},
|
||
{
|
||
"providerMetadata": {
|
||
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
||
"shortName": "CVE",
|
||
"dateUpdated": "2024-08-01T17:41:16.006Z"
|
||
},
|
||
"title": "CVE Program Container",
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"vendor-advisory",
|
||
"x_transferred"
|
||
],
|
||
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
|
||
}
|
||
]
|
||
}
|
||
]
|
||
}
|
||
} |