Files
vuln-cve/data/2024/0xxx/CVE-2024-0154.json
T

250 lines
10 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-0154",
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"state": "PUBLISHED",
"assignerShortName": "dell",
"dateReserved": "2023-12-14T05:29:25.760Z",
"datePublished": "2024-03-13T16:41:09.360Z",
"dateUpdated": "2024-08-01T17:41:16.006Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0 ",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0 ",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0 ",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0 ",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell",
"dateUpdated": "2024-03-13T16:41:09.360Z"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"title": "CISA ADP Vulnrichment",
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"id": "CVE-2024-0154",
"role": "CISA Coordinator",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-03-13T19:40:48.987776Z"
}
}
}
],
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-04T17:58:45.175Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-01T17:41:16.006Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
]
}
]
}
}