Files
vuln-cve/data/2023/6xxx/CVE-2023-6032.json
T

125 lines
4.9 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-6032",
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"state": "PUBLISHED",
"assignerShortName": "schneider",
"dateReserved": "2023-11-08T12:53:35.300Z",
"datePublished": "2023-11-15T03:54:35.655Z",
"dateUpdated": "2024-08-02T08:21:17.146Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Galaxy VS",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v6.82"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Galaxy VL",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v12.21"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')\nvulnerability exists that could cause a file system enumeration and file download when an\nattacker navigates to the Network Management Card via HTTPS.\n\n"
}
],
"value": "\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')\nvulnerability exists that could cause a file system enumeration and file download when an\nattacker navigates to the Network Management Card via HTTPS.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider",
"dateUpdated": "2023-11-15T03:54:35.655Z"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T08:21:17.146Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-03.pdf",
"tags": [
"x_transferred"
]
}
]
}
]
}
}