"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2023-4088",
|
|
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "Mitsubishi",
|
|
"dateReserved": "2023-08-02T04:52:49.923Z",
|
|
"datePublished": "2023-09-20T02:26:43.901Z",
|
|
"dateUpdated": "2024-09-24T18:27:11.655Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GX Works3",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "AL-PCS/WIN-E",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "CPU Module Logging Configuration Tool",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "EZSocket",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "FR Configurator2",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "FX Configurator-EN",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "FX Configurator-EN-L",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "FX Configurator-FP",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT Designer3 Version1(GOT1000)",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT Designer3 Version1(GOT2000)",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT SoftGOT1000 Version3",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT SoftGOT2000 Version1",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GX LogViewer",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GX Works2",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT FieldDeviceConfigurator",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT iQ AppPortal",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT MaiLab",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT Navigator",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT Update Manager",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MX Component",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MX Sheet",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "PX Developer",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "RT ToolBox3",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "RT VisualBox",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Data Transfer",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Data Transfer Classic",
|
|
"vendor": "Mitsubishi Electric Corporation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all versions"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder."
|
|
}
|
|
],
|
|
"value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder."
|
|
}
|
|
],
|
|
"impacts": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Malicious Code Execution"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "LOCAL",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.3,
|
|
"baseSeverity": "CRITICAL",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-276",
|
|
"description": "CWE-276 Incorrect Default Permissions",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
|
|
"shortName": "Mitsubishi",
|
|
"dateUpdated": "2024-07-04T09:16:28.950Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
|
|
},
|
|
{
|
|
"tags": [
|
|
"government-resource"
|
|
],
|
|
"url": "https://jvn.jp/vu/JVNVU96447193/index.html"
|
|
},
|
|
{
|
|
"tags": [
|
|
"government-resource"
|
|
],
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"title": "Malicious Code Execution Vulnerability in FA Engineering Software Products",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.1.0-dev"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-02T07:17:12.060Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
|
|
},
|
|
{
|
|
"tags": [
|
|
"government-resource",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://jvn.jp/vu/JVNVU96447193/index.html"
|
|
},
|
|
{
|
|
"tags": [
|
|
"government-resource",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-09-24T18:27:00.307770Z",
|
|
"id": "CVE-2023-4088",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-09-24T18:27:11.655Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |