252 lines
9.5 KiB
JSON
252 lines
9.5 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2023-47674",
|
|
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "jpcert",
|
|
"dateReserved": "2023-11-15T01:42:54.432Z",
|
|
"datePublished": "2023-11-16T07:28:38.522Z",
|
|
"dateUpdated": "2025-06-11T14:12:04.230Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "CFR-904E, CFR-908E, CFR-916E",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "CFR-4EHD, CFR-8EHD, CFR-16EHD",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "CFR-4EHA, CFR-8EHA, CFR-16EHA",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "CFR-4EAAM, CFR-4EABC",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "CFR-4EAA, CFR-8EAA, CFR-16EAA",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "CFR-4EAB, CFR-8EAB, CFR-16EAB",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "CFR-1004EA, CFR-1008EA, CFR-1016EA",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "MD-404HD, MD-808HD",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "MD-404HA, MD-808HA",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "MD-404AA, MD-808AA",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "First Co., Ltd.",
|
|
"product": "MD-404AB, MD-808AB",
|
|
"versions": [
|
|
{
|
|
"version": "firmware all versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Missing authentication for critical function vulnerability in First Corporation's DVRs allows a remote unauthenticated attacker to rewrite or obtain the configuration information of the affected device. Note that updates are provided only for Late model of CFR-4EABC, CFR-4EAB, CFR-8EAB, CFR-16EAB, MD-404AB, and MD-808AB. As for the other products, apply the workaround."
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"description": "Missing authentication for critical function",
|
|
"lang": "en",
|
|
"type": "text"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.c-first.co.jp/information/ddososhirase/"
|
|
},
|
|
{
|
|
"url": "https://www.c-first.co.jp/wp/wp-content/uploads/2023/11/tuushin.pdf"
|
|
},
|
|
{
|
|
"url": "https://jvn.jp/en/vu/JVNVU99077347/"
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
|
|
"shortName": "jpcert",
|
|
"dateUpdated": "2023-11-16T07:28:38.522Z"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-02T21:16:43.197Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://www.c-first.co.jp/information/ddososhirase/",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.c-first.co.jp/wp/wp-content/uploads/2023/11/tuushin.pdf",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://jvn.jp/en/vu/JVNVU99077347/",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-306",
|
|
"lang": "en",
|
|
"description": "CWE-306 Missing Authentication for Critical Function"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"scope": "UNCHANGED",
|
|
"version": "3.1",
|
|
"baseScore": 9.8,
|
|
"attackVector": "NETWORK",
|
|
"baseSeverity": "CRITICAL",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"integrityImpact": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"attackComplexity": "LOW",
|
|
"availabilityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"confidentialityImpact": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-06-11T14:11:19.703443Z",
|
|
"id": "CVE-2023-47674",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "yes"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-06-11T14:12:04.230Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |