180 lines
8.1 KiB
JSON
180 lines
8.1 KiB
JSON
{
|
||
"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.1",
|
||
"cveMetadata": {
|
||
"cveId": "CVE-2023-46290",
|
||
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
|
||
"state": "PUBLISHED",
|
||
"assignerShortName": "Rockwell",
|
||
"dateReserved": "2023-10-20T18:01:46.095Z",
|
||
"datePublished": "2023-10-27T18:10:50.923Z",
|
||
"dateUpdated": "2025-02-27T20:39:11.981Z"
|
||
},
|
||
"containers": {
|
||
"cna": {
|
||
"affected": [
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "FactoryTalk® Services Platform",
|
||
"vendor": "Rockwell Automation",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "versions before 2.80"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"type": "finder",
|
||
"user": "00000000-0000-4000-9000-000000000000",
|
||
"value": " This vulnerability was found internally during routine testing."
|
||
}
|
||
],
|
||
"datePublic": "2023-10-26T13:00:00.000Z",
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.</span>\n\n"
|
||
}
|
||
],
|
||
"value": "\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.\n\n"
|
||
}
|
||
],
|
||
"impacts": [
|
||
{
|
||
"capecId": "CAPEC-633",
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"value": "CAPEC-633 Token Impersonation"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV3_1": {
|
||
"attackComplexity": "HIGH",
|
||
"attackVector": "NETWORK",
|
||
"availabilityImpact": "HIGH",
|
||
"baseScore": 8.1,
|
||
"baseSeverity": "HIGH",
|
||
"confidentialityImpact": "HIGH",
|
||
"integrityImpact": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"scope": "UNCHANGED",
|
||
"userInteraction": "NONE",
|
||
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||
"version": "3.1"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-287",
|
||
"description": "CWE-287 Improper Authentication",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
|
||
"shortName": "Rockwell",
|
||
"dateUpdated": "2023-10-27T18:10:50.923Z"
|
||
},
|
||
"references": [
|
||
{
|
||
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165"
|
||
}
|
||
],
|
||
"solutions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "\n\n<ul><li>Install the respective <a target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx?crumb=113&versions=61602,60883,59837,59480,58564,57413,58591,59481,59482,59483,59484,59485,59486,59487,59488,59490,59491,59492,59493,59494,59495,59496\">FactoryTalk Services Version</a> that remediates the issue.</li><li><a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\">QA43240 - Recommended Security Guidelines from Rockwell Automation</a></li></ul>\n\n<br>"
|
||
}
|
||
],
|
||
"value": "\n * Install the respective FactoryTalk Services Version https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx that remediates the issue.\n * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\n\n\n"
|
||
}
|
||
],
|
||
"source": {
|
||
"discovery": "UNKNOWN"
|
||
},
|
||
"title": "Rockwell Automation FactoryTalk Services Platform Elevated Privileges Vulnerability",
|
||
"x_generator": {
|
||
"engine": "Vulnogram 0.1.0-dev"
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"providerMetadata": {
|
||
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
||
"shortName": "CVE",
|
||
"dateUpdated": "2024-08-02T20:45:40.833Z"
|
||
},
|
||
"title": "CVE Program Container",
|
||
"references": [
|
||
{
|
||
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165",
|
||
"tags": [
|
||
"x_transferred"
|
||
]
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"timestamp": "2025-02-26T21:49:21.323063Z",
|
||
"id": "CVE-2023-46290",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "no"
|
||
},
|
||
{
|
||
"Technical Impact": "total"
|
||
}
|
||
],
|
||
"role": "CISA Coordinator",
|
||
"version": "2.0.3"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"title": "CISA ADP Vulnrichment",
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2025-02-27T20:39:11.981Z"
|
||
}
|
||
}
|
||
]
|
||
}
|
||
} |