Files
vuln-cve/data/2023/45xxx/CVE-2023-45601.json
T

162 lines
6.2 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-45601",
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"state": "PUBLISHED",
"assignerShortName": "siemens",
"dateReserved": "2023-10-09T09:36:15.785Z",
"datePublished": "2023-10-10T10:21:47.253Z",
"dateUpdated": "2024-09-19T14:07:50.300Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens",
"dateUpdated": "2023-10-10T10:21:47.253Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)"
}
],
"affected": [
{
"vendor": "Siemens",
"product": "Parasolid V35.0",
"versions": [
{
"version": "All versions < V35.0.262",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Parasolid V35.1",
"versions": [
{
"version": "All versions < V35.1.250",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Parasolid V36.0",
"versions": [
{
"version": "All versions < V36.0.169",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2201",
"versions": [
{
"version": "All versions < V2201.0009",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2302",
"versions": [
{
"version": "All versions < V2302.0003",
"status": "affected"
}
],
"defaultStatus": "unknown"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf"
}
]
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T20:21:16.597Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf",
"tags": [
"x_transferred"
]
}
]
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-09-19T14:07:38.593206Z",
"id": "CVE-2023-45601",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-09-19T14:07:50.300Z"
}
}
]
}
}