Files
vuln-cve/data/2023/44xxx/CVE-2023-44109.json
T

137 lines
4.9 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-44109",
"assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"state": "PUBLISHED",
"assignerShortName": "huawei",
"dateReserved": "2023-09-25T09:11:04.625Z",
"datePublished": "2023-10-11T10:41:47.947Z",
"dateUpdated": "2024-08-02T19:59:50.707Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HarmonyOS",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "4.0.0"
},
{
"status": "affected",
"version": "3.1.0"
},
{
"status": "affected",
"version": "3.0.0"
},
{
"status": "affected",
"version": "2.1.0"
},
{
"status": "affected",
"version": "2.0.1"
},
{
"status": "affected",
"version": "2.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMUI",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "13.0.0"
},
{
"status": "affected",
"version": "12.0.1"
},
{
"status": "affected",
"version": "12.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Clone vulnerability in the huks ta module.Successful exploitation of this vulnerability may affect service confidentiality."
}
],
"value": "Clone vulnerability in the huks ta module.Successful exploitation of this vulnerability may affect service confidentiality."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"shortName": "huawei",
"dateUpdated": "2023-10-11T10:41:47.947Z"
},
"references": [
{
"url": "https://consumer.huawei.com/en/support/bulletin/2023/10/"
},
{
"url": "https://device.harmonyos.com/en/docs/security/update/security-bulletins-202310-0000001663676540"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T19:59:50.707Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://consumer.huawei.com/en/support/bulletin/2023/10/",
"tags": [
"x_transferred"
]
},
{
"url": "https://device.harmonyos.com/en/docs/security/update/security-bulletins-202310-0000001663676540",
"tags": [
"x_transferred"
]
}
]
}
]
}
}