Files
vuln-cve/data/2023/43xxx/CVE-2023-43477.json
T

178 lines
7.0 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-43477",
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"state": "PUBLISHED",
"assignerShortName": "tenable",
"dateReserved": "2023-09-18T17:35:17.960Z",
"datePublished": "2023-09-20T12:41:03.578Z",
"dateUpdated": "2024-09-24T19:00:27.334Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smart Modem Gen 2 (Arcadyan LH1000)",
"vendor": "Telstra",
"versions": [
{
"lessThan": "0.18.15r",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The ping_from parameter of ping_tracerte.cgi in the web UI of Telstra Smart Modem Gen 2 (Arcadyan LH1000), firmware versions < 0.18.15r, was not properly sanitized before being used in a system call, which could allow an authenticated attacker to achieve command injection as root on the device. "
}
],
"value": "The ping_from parameter of ping_tracerte.cgi in the web UI of Telstra Smart Modem Gen 2 (Arcadyan LH1000), firmware versions < 0.18.15r, was not properly sanitized before being used in a system call, which could allow an authenticated attacker to achieve command injection as root on the device. "
}
],
"impacts": [
{
"capecId": "CAPEC-248",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-248 Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable",
"dateUpdated": "2023-09-20T12:41:03.578Z"
},
"references": [
{
"url": "https://www.tenable.com/security/research/tra-2023-19"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Post-Auth Command Injection in Telstra Smart Modem Gen 2 (Arcadyan LH1000)",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T19:44:43.292Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.tenable.com/security/research/tra-2023-19",
"tags": [
"x_transferred"
]
}
]
},
{
"affected": [
{
"vendor": "telstra",
"product": "arcadyan_lh1000",
"cpes": [
"cpe:2.3:h:telstra:arcadyan_lh1000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "0",
"status": "affected",
"lessThan": "0.18.15r",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-09-24T18:59:33.342788Z",
"id": "CVE-2023-43477",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-09-24T19:00:27.334Z"
}
}
]
}
}