Files
vuln-cve/data/2023/39xxx/CVE-2023-39226.json
T

140 lines
5.9 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-39226",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2023-11-15T20:41:11.035Z",
"datePublished": "2023-11-30T22:05:36.057Z",
"dateUpdated": "2024-08-02T18:02:06.472Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "InfraSuite Device Master",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "hir0ot and Piotr Bazydlo (@chudypb) working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"datePublic": "2023-11-08T18:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet.</span>\n\n</span>\n\n</span>"
}
],
"value": "In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749 Exposed Dangerous Method Or Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2023-11-30T22:05:36.057Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<span style=\"background-color: rgb(255, 255, 255);\">Delta Electronics recommends updating their software to </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.10.exe\">v1.0.10</a><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;or later.</span>\n\n<br>"
}
],
"value": "Delta Electronics recommends updating their software to v1.0.10 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.10.exe  or later."
}
],
"source": {
"advisory": "ICSA-23-331-01",
"discovery": "EXTERNAL"
},
"title": "Delta Electronics InfraSuite Device Master Exposed Dangerous Method Or Function",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T18:02:06.472Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01",
"tags": [
"x_transferred"
]
}
]
}
]
}
}