Files
vuln-cve/data/2023/39xxx/CVE-2023-39171.json
T

158 lines
5.6 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2023-39171",
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"state": "PUBLISHED",
"assignerShortName": "CERTVDE",
"dateReserved": "2023-07-25T14:06:01.345Z",
"datePublished": "2023-12-07T14:23:57.124Z",
"dateUpdated": "2025-11-04T19:17:39.942Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Storage Box V1",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "before Nov. 2023"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Storage Box V2",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "before Nov. 2023"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Storage Box V3",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "before Nov. 2023"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Ph0s[4]"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "R0ckE7"
}
],
"datePublic": "2023-12-07T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SENEC Storage Box V1,V2 and V3 accidentially expose a management UI accessible with publicly known admin credentials."
}
],
"value": "SENEC Storage Box V1,V2 and V3 accidentially expose a management UI accessible with publicly known admin credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE",
"dateUpdated": "2023-12-07T14:23:57.124Z"
},
"references": [
{
"url": "https://seclists.org/fulldisclosure/2023/Nov/2"
}
],
"source": {
"defect": [
"CERT@VDE#64567"
],
"discovery": "UNKNOWN"
},
"title": "SENEC Storage Box V1,V2 and V3 accidentially expose a management interface",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"title": "CVE Program Container",
"references": [
{
"url": "https://seclists.org/fulldisclosure/2023/Nov/2",
"tags": [
"x_transferred"
]
},
{
"url": "http://seclists.org/fulldisclosure/2023/Nov/2"
}
],
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2025-11-04T19:17:39.942Z"
}
}
]
}
}