165 lines
6.6 KiB
JSON
165 lines
6.6 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2023-32467",
|
|
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "dell",
|
|
"dateReserved": "2023-05-09T06:07:41.363Z",
|
|
"datePublished": "2024-07-10T02:39:47.352Z",
|
|
"dateUpdated": "2024-08-02T15:18:37.188Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "PowerSwitch Z9664F-ON BIOS",
|
|
"vendor": "Dell",
|
|
"versions": [
|
|
{
|
|
"lessThan": "v1.05.10",
|
|
"status": "affected",
|
|
"version": "N/A",
|
|
"versionType": "semver"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"type": "finder",
|
|
"value": "Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue"
|
|
},
|
|
{
|
|
"lang": "en",
|
|
"type": "finder",
|
|
"value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues"
|
|
}
|
|
],
|
|
"datePublic": "2023-06-14T06:30:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
|
|
}
|
|
],
|
|
"value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "LOCAL",
|
|
"availabilityImpact": "LOW",
|
|
"baseScore": 5.7,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-665",
|
|
"description": "CWE-665: Improper Initialization",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
|
|
"shortName": "dell",
|
|
"dateUpdated": "2024-07-10T02:39:47.352Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.2.0"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-07-31T15:53:25.320608Z",
|
|
"id": "CVE-2023-32467",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-07-31T15:53:33.059Z"
|
|
}
|
|
},
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-02T15:18:37.188Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |