Files
vuln-cve/data/2023/30xxx/CVE-2023-30546.json
T

161 lines
6.8 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-30546",
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"state": "PUBLISHED",
"assignerShortName": "GitHub_M",
"dateReserved": "2023-04-12T15:19:33.767Z",
"datePublished": "2023-04-26T18:14:46.436Z",
"dateUpdated": "2025-01-30T21:31:28.154Z"
},
"containers": {
"cna": {
"title": "Contiki-NG has off-by-one error in Antelope DBMS",
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"lang": "en",
"description": "CWE-125: Out-of-bounds Read",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-193",
"lang": "en",
"description": "CWE-193: Off-by-one Error",
"type": "CWE"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"references": [
{
"name": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-257g-w39m-5jj4",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-257g-w39m-5jj4"
},
{
"name": "https://github.com/contiki-ng/contiki-ng/pull/2425",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/contiki-ng/contiki-ng/pull/2425"
}
],
"affected": [
{
"vendor": "contiki-ng",
"product": "contiki-ng",
"versions": [
{
"version": "<= 4.8",
"status": "affected"
}
]
}
],
"providerMetadata": {
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M",
"dateUpdated": "2023-04-26T18:14:46.436Z"
},
"descriptions": [
{
"lang": "en",
"value": "Contiki-NG is an operating system for Internet of Things devices. An off-by-one error can be triggered in the Antelope database management system in the Contiki-NG operating system in versions 4.8 and prior. The problem exists in the Contiki File System (CFS) backend for the storage of data (file os/storage/antelope/storage-cfs.c). In the functions `storage_get_index` and `storage_put_index`, a buffer for merging two strings is allocated with one byte less than the maximum size of the merged strings, causing subsequent function calls to the cfs_open function to read from memory beyond the buffer size. The vulnerability has been patched in the \"develop\" branch of Contiki-NG, and is expected to be included in the next release. As a workaround, the problem can be fixed by applying the patch in Contiki-NG pull request #2425."
}
],
"source": {
"advisory": "GHSA-257g-w39m-5jj4",
"discovery": "UNKNOWN"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T14:28:51.792Z"
},
"title": "CVE Program Container",
"references": [
{
"name": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-257g-w39m-5jj4",
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-257g-w39m-5jj4"
},
{
"name": "https://github.com/contiki-ng/contiki-ng/pull/2425",
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/contiki-ng/contiki-ng/pull/2425"
}
]
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-01-30T21:31:24.927916Z",
"id": "CVE-2023-30546",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-01-30T21:31:28.154Z"
}
}
]
}
}