Files
vuln-cve/data/2023/29xxx/CVE-2023-29158.json
T

184 lines
8.9 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-29158",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2023-05-25T16:04:56.578Z",
"datePublished": "2023-06-19T20:11:05.873Z",
"dateUpdated": "2024-12-09T20:49:14.599Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center",
"vendor": "SUBNET Solutions Inc.",
"versions": [
{
"lessThanOrEqual": "2020 U10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SUBNET Solutions reported these vulnerabilities to CISA."
}
],
"datePublic": "2023-06-15T20:07:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<p>\n\n<span style=\"background-color: rgb(255, 255, 255);\">SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.</span>\n\n</p><br>\n\n"
}
],
"value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2023-06-19T20:11:05.873Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<p>SUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).</p><p><br></p>"
}
],
"value": "\nSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\n\n\n\n\n"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "SUBNET PowerSYSTEM Center Authentication Bypass by Capture-replay",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<p>SUBNET Solutions recommends users to follow the following workarounds:</p><ul><li>Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.</li><li>Users should verify network security rules to ensure that outbound connections to the internet are not possible.</li><li>If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.</li><li>Monitor user activity and ensure application control rules only allow preauthorized executables to run.</li><li>Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).</li></ul><br>\n\n<br>"
}
],
"value": "\nSUBNET Solutions recommends users to follow the following workarounds:\n\n * Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\n * Users should verify network security rules to ensure that outbound connections to the internet are not possible.\n * If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\n * Monitor user activity and ensure application control rules only allow preauthorized executables to run.\n * Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\n\n\n\n\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T14:00:15.368Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01",
"tags": [
"x_transferred"
]
}
]
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-12-09T20:48:57.979110Z",
"id": "CVE-2023-29158",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-12-09T20:49:14.599Z"
}
}
]
}
}