Files
vuln-cve/data/2023/25xxx/CVE-2023-25719.json
T

158 lines
6.5 KiB
JSON

{
"dataType": "CVE_RECORD",
"cveMetadata": {
"state": "PUBLISHED",
"cveId": "CVE-2023-25719",
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"dateUpdated": "2025-06-19T20:35:43.320Z",
"dateReserved": "2023-02-13T00:00:00.000Z",
"datePublished": "2023-02-13T00:00:00.000Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre",
"dateUpdated": "2025-06-19T20:35:43.320Z"
},
"descriptions": [
{
"lang": "en",
"value": "ConnectWise Control before 22.9.10032 (formerly known as ScreenConnect) fails to validate user-supplied parameters such as the Bin/ConnectWiseControl.Client.exe h parameter. This results in reflected data and injection of malicious code into a downloaded executable. The executable can be used to execute malicious queries or as a denial-of-service vector. NOTE: this CVE Record is only about the parameters, such as the h parameter (this CVE Record is not about the separate issue of signed executable files that are supposed to have unique configurations across customers' installations)."
}
],
"affected": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"version": "n/a",
"status": "affected"
}
]
}
],
"references": [
{
"url": "https://cybir.com/2022/cve/hijacking-connectwise-control-and-ddos/"
},
{
"url": "https://www.connectwise.com/blog/cybersecurity/the-importance-of-responsible-security-disclosures"
},
{
"url": "https://m.youtube.com/watch?v=fbNVUgmstSc&pp=0gcJCf0Ao7VqN5tD"
}
],
"problemTypes": [
{
"descriptions": [
{
"type": "text",
"lang": "en",
"description": "n/a"
}
]
}
]
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T11:32:11.873Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.connectwise.com",
"tags": [
"x_transferred"
]
},
{
"url": "https://cybir.com/2022/cve/hijacking-connectwise-control-and-ddos/",
"tags": [
"x_transferred"
]
},
{
"url": "https://www.huntress.com/blog/clearing-the-air-overblown-claims-of-vulnerabilities-exploits-severity",
"tags": [
"x_transferred"
]
},
{
"url": "https://www.connectwise.com/blog/cybersecurity/the-importance-of-responsible-security-disclosures",
"tags": [
"x_transferred"
]
}
]
},
{
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-74",
"lang": "en",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
}
},
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-03-21T14:53:49.916588Z",
"id": "CVE-2023-25719",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-03-21T14:54:25.416Z"
}
}
]
},
"dataVersion": "5.1"
}