Files
vuln-cve/data/2023/24xxx/CVE-2023-24503.json
T

155 lines
5.6 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"state": "PUBLISHED",
"cveId": "CVE-2023-24503",
"assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"assignerShortName": "INCD",
"dateUpdated": "2025-02-06T15:18:56.447Z",
"dateReserved": "2023-01-24T00:00:00.000Z",
"datePublished": "2023-04-17T00:00:00.000Z"
},
"containers": {
"cna": {
"title": " Electra Smart Kit for Split AC – Adjacent attacker may cause the unit to load unauthorized FW",
"datePublic": "2023-04-17T00:00:00.000Z",
"providerMetadata": {
"orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"shortName": "INCD",
"dateUpdated": "2023-04-17T00:00:00.000Z"
},
"descriptions": [
{
"lang": "en",
"value": "Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW."
}
],
"affected": [
{
"vendor": "Electra",
"product": "OSK201",
"versions": [
{
"version": "Update to the latest version",
"status": "affected",
"lessThan": "Update to the latest version*",
"versionType": "custom"
}
]
}
],
"references": [
{
"url": "https://www.gov.il/en/Departments/faq/cve_advisories"
}
],
"credits": [
{
"lang": "en",
"value": "Lev Aronsky, Idan Strovinsky"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"type": "text",
"lang": "en",
"description": "Adjacent attacker may cause the unit to load unauthorized FW"
}
]
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"source": {
"defect": [
"ILVN-2023-0090"
],
"discovery": "UNKNOWN"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T10:56:04.348Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.gov.il/en/Departments/faq/cve_advisories",
"tags": [
"x_transferred"
]
}
]
},
{
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-494",
"lang": "en",
"description": "CWE-494 Download of Code Without Integrity Check"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-02-06T15:17:49.550387Z",
"id": "CVE-2023-24503",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-02-06T15:18:56.447Z"
}
}
]
}
}