Files
vuln-cve/data/2023/20xxx/CVE-2023-20169.json
T

109 lines
4.8 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-20169",
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"state": "PUBLISHED",
"assignerShortName": "cisco",
"dateReserved": "2022-10-27T18:47:50.362Z",
"datePublished": "2023-08-23T18:19:45.317Z",
"dateUpdated": "2024-08-02T09:05:36.905Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco",
"dateUpdated": "2024-01-25T16:57:49.042Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Intermediate System-to-Intermediate System (IS-IS) protocol of Cisco NX-OS Software for the Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly restart, which could cause an affected device to reload.\r\n\r This vulnerability is due to insufficient input validation when parsing an ingress IS-IS packet. An attacker could exploit this vulnerability by sending a crafted IS-IS packet to an affected device. A successful exploit could allow the attacker to cause a denial of service (DoS) condition due to the unexpected restart of the IS-IS process, which could cause the affected device to reload. Note: The IS-IS protocol is a routing protocol. To exploit this vulnerability, an attacker must be Layer 2 adjacent to the affected device."
}
],
"affected": [
{
"vendor": "Cisco",
"product": "Cisco NX-OS Software",
"versions": [
{
"version": "10.3(2)",
"status": "affected"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"description": "Access of Memory Location After End of Buffer",
"type": "cwe",
"cweId": "CWE-788"
}
]
}
],
"references": [
{
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-nxos-n3_9k-isis-dos-FTCXB4Vb",
"name": "cisco-sa-nxos-n3_9k-isis-dos-FTCXB4Vb"
}
],
"metrics": [
{
"format": "cvssV3_1",
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
}
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"source": {
"advisory": "cisco-sa-nxos-n3_9k-isis-dos-FTCXB4Vb",
"discovery": "INTERNAL",
"defects": [
"CSCwe11136"
]
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T09:05:36.905Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-nxos-n3_9k-isis-dos-FTCXB4Vb",
"name": "cisco-sa-nxos-n3_9k-isis-dos-FTCXB4Vb",
"tags": [
"x_transferred"
]
}
]
}
]
}
}