"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2023-0123",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2023-01-09T19:11:48.371Z",
"datePublished": "2023-02-02T22:57:48.508Z",
"dateUpdated": "2025-01-16T21:58:05.233Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DOPSoft",
"vendor": "Delta Industrial Automation",
"versions": [
{
"lessThanOrEqual": "4.00.16.22",
"status": "affected",
"version": "all versions",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Natnael Samson (@NattiSamson), working with Trend Micro’s Zero Day Initiative"
}
],
"datePublic": "2023-01-31T15:45:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<p>Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.</p>"
}
],
"value": "Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2023-02-02T22:57:48.508Z"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-031-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Delta Electronics released </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://deltaiastudio.b2clogin.com/deltaiastudio.onmicrosoft.com/oauth2/v2.0/authorize?p=b2c_1_diastudiosigninup&amp;client_id=9092aab8-5ccc-4a8a-a76a-59b00b7d0d52&amp;redirect_uri=https%3a%2f%2fdiastudio.deltaww.com%2f&amp;response_mode=form_post&amp;response_type=id_token&amp;scope=openid&amp;state=OpenIdConnect.AuthenticationProperties%3dtSXw0hKpEQ9vkkvdbqbshwzywJBnOgHxqapYQrEFN1e07YOvSVHV4JuCnsD_u70KLfNuS1hKhM-fxE-PWfcOiK5DvJawVerhuz5N06I2xkJWLrZ0yh9PwixawgeMnt-gu8pNLCmqRH8jRkrirPp2XMz3lu8Qd1AmJGdk9xRhIziSEbdEjF0X8r2D4klk7yno&amp;nonce=638084927799189443.NTVmNmFmNDMtYjNmMC00ZWY0LWI3ZjQtYzA0NTI0NTE5MTVmODE0MGU5ZGItNDhhMy00MDI5LTk4NWQtYzUxNjJkOGJiYmI1&amp;ui_locales=en-US&amp;x-client-SKU=ID_NET&amp;x-client-ver=1.0.40306.1554#catalog\">version 1.3.0 of DIAScreen</a><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;(login required) and recommends users to use DIAScreen instead of DOPSoft. </span>\n\n<br>"
}
],
"value": "\nDelta Electronics released version 1.3.0 of DIAScreen https://deltaiastudio.b2clogin.com/deltaiastudio.onmicrosoft.com/oauth2/v2.0/authorize  (login required) and recommends users to use DIAScreen instead of DOPSoft. \n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "CVE-2023-0123",
"x_generator": {
"engine": "VINCE 2.0.6",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2023-0123"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T05:02:43.755Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-031-01",
"tags": [
"x_transferred"
]
}
]
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-01-16T20:32:04.009740Z",
"id": "CVE-2023-0123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-01-16T21:58:05.233Z"
}
}
]
}
}