"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"state": "PUBLISHED",
"cveId": "CVE-2022-48174",
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"dateUpdated": "2026-07-14T11:54:14.009Z",
"dateReserved": "2022-12-29T00:00:00.000Z",
"datePublished": "2023-08-22T00:00:00.000Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre",
"dateUpdated": "2023-08-22T15:44:17.734Z"
},
"descriptions": [
{
"lang": "en",
"value": "There is a stack overflow vulnerability in ash.c:6030 in busybox before 1.35. In the environment of Internet of Vehicles, this vulnerability can be executed from command to arbitrary code execution."
}
],
"affected": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"version": "n/a",
"status": "affected"
}
]
}
],
"references": [
{
"url": "https://bugs.busybox.net/show_bug.cgi?id=15216"
}
],
"problemTypes": [
{
"descriptions": [
{
"type": "text",
"lang": "en",
"description": "n/a"
}
]
}
]
},
"adp": [
{
"title": "CVE Program Container",
"references": [
{
"url": "https://bugs.busybox.net/show_bug.cgi?id=15216",
"tags": [
"x_transferred"
]
},
{
"url": "https://security.netapp.com/advisory/ntap-20241129-0001/"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2025/01/msg00012.html"
}
],
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2025-11-03T20:35:11.485Z"
}
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-10-03T14:24:43.462618Z",
"id": "CVE-2022-48174",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-10-03T14:24:51.861Z"
}
},
{
"x_adpType": "supplier",
"providerMetadata": {
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP",
"dateUpdated": "2026-07-14T11:54:14.009Z"
},
"affected": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM RST2428P",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XCH328",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XCM324",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XCM328",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XCM332",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRH334 (24 V DC, 8xFO, CC)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (230 V AC, 12xFO)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (230 V AC, 8xFO)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (24 V DC, 12xFO)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (24 V DC, 8xFO)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (2x230 V AC, 12xFO)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (2x230 V AC, 8xFO)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V3.3",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIDIS Secured SmartPlug",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V7.26.0310",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-089022.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-585531.html"
}
]
}
]
}
}