118 lines
4.4 KiB
JSON
118 lines
4.4 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2022-46141",
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "siemens",
|
|
"dateReserved": "2022-11-28T16:50:58.483Z",
|
|
"datePublished": "2023-12-12T11:25:26.583Z",
|
|
"dateUpdated": "2024-11-25T21:17:26.263Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens",
|
|
"dateUpdated": "2023-12-12T11:25:26.583Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 (TIA Portal)",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V19",
|
|
"status": "affected"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
|
|
"baseScore": 4.2,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-316",
|
|
"description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-03T14:24:03.267Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-11-25T21:17:05.789021Z",
|
|
"id": "CVE-2022-46141",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-11-25T21:17:26.263Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |