Files
vuln-cve/data/2022/45xxx/CVE-2022-45147.json
T

269 lines
11 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2022-45147",
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"state": "PUBLISHED",
"assignerShortName": "siemens",
"dateReserved": "2022-11-11T08:33:16.611Z",
"datePublished": "2024-07-09T12:04:22.545Z",
"dateUpdated": "2025-08-27T20:32:52.249Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens",
"dateUpdated": "2024-07-09T12:04:22.545Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\r\n\r\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300."
}
],
"affected": [
{
"vendor": "Siemens",
"product": "SIMATIC PCS neo V4.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC STEP 7 V16",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC STEP 7 V17",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC STEP 7 V18",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V18 Update 2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
},
{
"cvssV4_0": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"baseScore": 8.5,
"baseSeverity": "HIGH"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-825651.html"
}
]
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"id": "CVE-2022-45147",
"role": "CISA Coordinator",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-07-09T13:30:52.115552Z"
}
}
}
],
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_pcs_neo:4.0:-:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "simatic_pcs_neo",
"versions": [
{
"status": "affected",
"version": "4.0",
"lessThan": "5.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "simatic_step_7",
"versions": [
{
"status": "affected",
"version": "16",
"lessThan": "17",
"versionType": "custom"
},
{
"status": "affected",
"version": "17",
"lessThan": "18",
"versionType": "custom"
},
{
"status": "affected",
"version": "18",
"lessThan": "18_update_2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "simatic_step_7",
"versions": [
{
"status": "affected",
"version": "16",
"lessThan": "17",
"versionType": "custom"
},
{
"status": "affected",
"version": "17",
"lessThan": "18",
"versionType": "custom"
},
{
"status": "affected",
"version": "18",
"lessThan": "18_update_2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "simatic_step_7",
"versions": [
{
"status": "affected",
"version": "16",
"lessThan": "17",
"versionType": "custom"
},
{
"status": "affected",
"version": "17",
"lessThan": "18",
"versionType": "custom"
},
{
"status": "affected",
"version": "18",
"lessThan": "18_update_2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-08-27T20:32:52.249Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T14:09:56.615Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-825651.html",
"tags": [
"x_transferred"
]
}
]
}
]
}
}