"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"state": "PUBLISHED",
"cveId": "CVE-2022-43398",
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"dateUpdated": "2024-08-03T13:32:58.148Z",
"dateReserved": "2022-10-18T00:00:00.000Z",
"datePublished": "2022-11-08T00:00:00.000Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens",
"dateUpdated": "2024-01-09T09:57:13.900Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session."
}
],
"affected": [
{
"vendor": "Siemens",
"product": "POWER METER SICAM Q100",
"versions": [
{
"version": "All versions < V2.50",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "POWER METER SICAM Q100",
"versions": [
{
"version": "All versions < V2.50",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "POWER METER SICAM Q100",
"versions": [
{
"version": "All versions < V2.50",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "POWER METER SICAM Q100",
"versions": [
{
"version": "All versions < V2.50",
"status": "affected"
}
],
"defaultStatus": "unknown"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 7.5,
"baseSeverity": "HIGH"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-384",
"description": "CWE-384: Session Fixation",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
}
]
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T13:32:58.148Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf",
"tags": [
"x_transferred"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf",
"tags": [
"x_transferred"
]
}
]
}
]
}
}