"dataType": "CVE_RECORD",
|
|
"cveMetadata": {
|
|
"state": "PUBLISHED",
|
|
"cveId": "CVE-2022-43110",
|
|
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"assignerShortName": "mitre",
|
|
"dateUpdated": "2025-08-22T20:25:23.662Z",
|
|
"dateReserved": "2022-10-17T00:00:00.000Z",
|
|
"datePublished": "2025-08-22T00:00:00.000Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"shortName": "mitre",
|
|
"dateUpdated": "2025-08-22T19:34:35.786Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "n/a",
|
|
"product": "n/a",
|
|
"versions": [
|
|
{
|
|
"version": "n/a",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.ready2disclose.com/vpow-31491-43110/"
|
|
},
|
|
{
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-182-05"
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "text",
|
|
"lang": "en",
|
|
"description": "n/a"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-425",
|
|
"lang": "en",
|
|
"description": "CWE-425 Direct Request ('Forced Browsing')"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-306",
|
|
"lang": "en",
|
|
"description": "CWE-306 Missing Authentication for Critical Function"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-284",
|
|
"lang": "en",
|
|
"description": "CWE-284 Improper Access Control"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"scope": "UNCHANGED",
|
|
"version": "3.1",
|
|
"baseScore": 9.8,
|
|
"attackVector": "NETWORK",
|
|
"baseSeverity": "CRITICAL",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"integrityImpact": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"attackComplexity": "LOW",
|
|
"availabilityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"confidentialityImpact": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-08-22T20:23:45.457505Z",
|
|
"id": "CVE-2022-43110",
|
|
"options": [
|
|
{
|
|
"Exploitation": "poc"
|
|
},
|
|
{
|
|
"Automatable": "yes"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-08-22T20:25:23.662Z"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"dataVersion": "5.1"
|
|
} |