362 lines
15 KiB
JSON
362 lines
15 KiB
JSON
{
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "Compact Controller CC100 (751-9301)",
|
|
"vendor": "WAGO",
|
|
"versions": [
|
|
{
|
|
"lessThan": "FW22",
|
|
"status": "affected",
|
|
"version": "FW16",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Edge Controller (752-8303/8000-002)",
|
|
"vendor": "WAGO",
|
|
"versions": [
|
|
{
|
|
"lessThan": "FW22",
|
|
"status": "affected",
|
|
"version": "FW16",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Series PFC100 (750-81xx/xxx-xxx)",
|
|
"vendor": "WAGO",
|
|
"versions": [
|
|
{
|
|
"lessThan": "FW22",
|
|
"status": "affected",
|
|
"version": "FW16",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Series PFC200 (750-82xx/xxx-xxx)",
|
|
"vendor": "WAGO",
|
|
"versions": [
|
|
{
|
|
"lessThan": "FW22",
|
|
"status": "affected",
|
|
"version": "FW16",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
|
|
"vendor": "WAGO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "FW16 FW22"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Series Touch Panel 600 Marine Line (762-6xxx)",
|
|
"vendor": "WAGO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "FW16 FW22"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Series Touch Panel 600 Standard Line (762-4xxx)",
|
|
"vendor": "WAGO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "FW16 FW22"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
|
|
}
|
|
],
|
|
"datePublic": "2022-03-09T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.4,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
|
|
"version": "3.1"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-79",
|
|
"description": "CWE-79 Cross-site Scripting (XSS)",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-03-09T19:38:43.000Z",
|
|
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
|
|
"shortName": "CERTVDE"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM"
|
|
],
|
|
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
|
|
}
|
|
],
|
|
"solutions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Install FW >=FW22 (FW22 planned for end of Q2/22)"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "VDE-2022-004",
|
|
"defect": [
|
|
"CERT@VDE#64068"
|
|
],
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"title": "WAGO PLCs WBM vulnerable to reflected XSS",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "info@cert.vde.com",
|
|
"DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
|
|
"ID": "CVE-2022-22511",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Compact Controller CC100 (751-9301)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "FW16",
|
|
"version_value": "FW22"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Edge Controller (752-8303/8000-002)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "FW16",
|
|
"version_value": "FW22"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Series PFC100 (750-81xx/xxx-xxx)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "FW16",
|
|
"version_value": "FW22"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Series PFC200 (750-82xx/xxx-xxx)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "FW16",
|
|
"version_value": "FW22"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_name": "FW16",
|
|
"version_value": "FW22"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_name": "FW16",
|
|
"version_value": "FW22"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_name": "FW16",
|
|
"version_value": "FW22"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "WAGO"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"credit": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
|
|
}
|
|
],
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.4,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-79 Cross-site Scripting (XSS)"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
|
|
"refsource": "CONFIRM",
|
|
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Install FW >=FW22 (FW22 planned for end of Q2/22)"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "VDE-2022-004",
|
|
"defect": [
|
|
"CERT@VDE#64068"
|
|
],
|
|
"discovery": "EXTERNAL"
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-03T03:14:55.300Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
|
|
"assignerShortName": "CERTVDE",
|
|
"cveId": "CVE-2022-22511",
|
|
"datePublished": "2022-03-09T19:38:43.516Z",
|
|
"dateReserved": "2022-01-03T00:00:00.000Z",
|
|
"dateUpdated": "2024-09-17T00:16:00.059Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |