Files
vuln-cve/data/2022/0xxx/CVE-2022-0902.json
T

362 lines
16 KiB
JSON

{
"containers": {
"cna": {
"affected": [
{
"product": "RMC-100 (Standard)",
"vendor": "ABB",
"versions": [
{
"lessThan": "2105457-037",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "RMC-100-LITE",
"vendor": "ABB",
"versions": [
{
"lessThan": "2106229-011",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "XIO",
"vendor": "ABB",
"versions": [
{
"lessThan": "2106198-008",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "XFCG5",
"vendor": "ABB",
"versions": [
{
"lessThan": "2105805-016",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "XRCG5",
"vendor": "ABB",
"versions": [
{
"lessThan": "2105864-016",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "uFLOG5",
"vendor": "ABB",
"versions": [
{
"lessThan": "2105298-024",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "UDC",
"vendor": "ABB",
"versions": [
{
"lessThan": "2106177-007",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers."
}
],
"datePublic": "2022-07-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-21T15:34:49.000Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"DATE_PUBLIC": "2022-07-14T06:51:00.000Z",
"ID": "CVE-2022-0902",
"STATE": "PUBLIC",
"TITLE": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RMC-100 (Standard)",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2105457-037"
}
]
}
},
{
"product_name": "RMC-100-LITE",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2106229-011"
}
]
}
},
{
"product_name": "XIO",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2106198-008"
}
]
}
},
{
"product_name": "XFCG5",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2105805-016"
}
]
}
},
{
"product_name": "XRCG5",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2105864-016"
}
]
}
},
{
"product_name": "uFLOG5",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2105298-024"
}
]
}
},
{
"product_name": "UDC",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2106177-007"
}
]
}
}
]
},
"vendor_name": "ABB"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga",
"refsource": "MISC",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-02T23:47:42.131Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927&LanguageCode=en&DocumentPartId=&Action=Launch&_ga"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-0902",
"datePublished": "2022-07-21T15:34:49.705Z",
"dateReserved": "2022-03-09T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:00:38.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}