8821 lines
362 KiB
JSON
8821 lines
362 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"cveMetadata": {
|
|
"state": "PUBLISHED",
|
|
"cveId": "CVE-2022-0778",
|
|
"assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
|
|
"assignerShortName": "openssl",
|
|
"dateUpdated": "2026-10-14T12:12:36.346Z",
|
|
"dateReserved": "2022-02-28T00:00:00.000Z",
|
|
"datePublished": "2022-03-15T17:05:20.382Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"title": "Infinite loop in BN_mod_sqrt() reachable when parsing certificates",
|
|
"datePublic": "2022-03-15T00:00:00.000Z",
|
|
"providerMetadata": {
|
|
"orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
|
|
"shortName": "openssl",
|
|
"dateUpdated": "2024-06-21T19:07:01.186Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "OpenSSL",
|
|
"product": "OpenSSL",
|
|
"versions": [
|
|
{
|
|
"version": "Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1)",
|
|
"status": "affected"
|
|
},
|
|
{
|
|
"version": "Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m)",
|
|
"status": "affected"
|
|
},
|
|
{
|
|
"version": "Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.openssl.org/news/secadv/20220315.txt"
|
|
},
|
|
{
|
|
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
|
|
},
|
|
{
|
|
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
|
|
},
|
|
{
|
|
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
|
|
},
|
|
{
|
|
"name": "DSA-5103",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://www.debian.org/security/2022/dsa-5103"
|
|
},
|
|
{
|
|
"name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2952-1] openssl security update",
|
|
"tags": [
|
|
"mailing-list"
|
|
],
|
|
"url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
|
|
},
|
|
{
|
|
"name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2953-1] openssl1.0 security update",
|
|
"tags": [
|
|
"mailing-list"
|
|
],
|
|
"url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
|
|
},
|
|
{
|
|
"name": "FEDORA-2022-a5f51502f0",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
|
|
},
|
|
{
|
|
"name": "FEDORA-2022-9e88b5d8d7",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
|
|
},
|
|
{
|
|
"name": "FEDORA-2022-8bb51f6901",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
|
|
},
|
|
{
|
|
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
|
|
},
|
|
{
|
|
"url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
|
|
},
|
|
{
|
|
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-06"
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-07"
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-08"
|
|
},
|
|
{
|
|
"name": "20220516 APPLE-SA-2022-05-16-4 Security Update 2022-004 Catalina",
|
|
"tags": [
|
|
"mailing-list"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/May/33"
|
|
},
|
|
{
|
|
"name": "20220516 APPLE-SA-2022-05-16-3 macOS Big Sur 11.6.6",
|
|
"tags": [
|
|
"mailing-list"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/May/35"
|
|
},
|
|
{
|
|
"name": "20220516 APPLE-SA-2022-05-16-2 macOS Monterey 12.4",
|
|
"tags": [
|
|
"mailing-list"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/May/38"
|
|
},
|
|
{
|
|
"url": "https://www.oracle.com/security-alerts/cpujul2022.html"
|
|
},
|
|
{
|
|
"url": "https://support.apple.com/kb/HT213257"
|
|
},
|
|
{
|
|
"url": "https://support.apple.com/kb/HT213256"
|
|
},
|
|
{
|
|
"url": "https://support.apple.com/kb/HT213255"
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-09"
|
|
},
|
|
{
|
|
"url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
|
|
},
|
|
{
|
|
"url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
|
|
},
|
|
{
|
|
"name": "GLSA-202210-02",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://security.gentoo.org/glsa/202210-02"
|
|
},
|
|
{
|
|
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Tavis Ormandy (Google)"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "unknown",
|
|
"content": {
|
|
"lang": "eng",
|
|
"url": "https://www.openssl.org/policies/secpolicy.html#High",
|
|
"value": "High"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "text",
|
|
"lang": "en",
|
|
"description": "Infinite loop"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-02T23:40:03.765Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://www.openssl.org/news/secadv/20220315.txt",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"name": "DSA-5103",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.debian.org/security/2022/dsa-5103"
|
|
},
|
|
{
|
|
"name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2952-1] openssl security update",
|
|
"tags": [
|
|
"mailing-list",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
|
|
},
|
|
{
|
|
"name": "[debian-lts-announce] 20220317 [SECURITY] [DLA 2953-1] openssl1.0 security update",
|
|
"tags": [
|
|
"mailing-list",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
|
|
},
|
|
{
|
|
"name": "FEDORA-2022-a5f51502f0",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
|
|
},
|
|
{
|
|
"name": "FEDORA-2022-9e88b5d8d7",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
|
|
},
|
|
{
|
|
"name": "FEDORA-2022-8bb51f6901",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
|
|
},
|
|
{
|
|
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://security.netapp.com/advisory/ntap-20220321-0002/",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-06",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-07",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-08",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"name": "20220516 APPLE-SA-2022-05-16-4 Security Update 2022-004 Catalina",
|
|
"tags": [
|
|
"mailing-list",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/May/33"
|
|
},
|
|
{
|
|
"name": "20220516 APPLE-SA-2022-05-16-3 macOS Big Sur 11.6.6",
|
|
"tags": [
|
|
"mailing-list",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/May/35"
|
|
},
|
|
{
|
|
"name": "20220516 APPLE-SA-2022-05-16-2 macOS Monterey 12.4",
|
|
"tags": [
|
|
"mailing-list",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/May/38"
|
|
},
|
|
{
|
|
"url": "https://www.oracle.com/security-alerts/cpujul2022.html",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://support.apple.com/kb/HT213257",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://support.apple.com/kb/HT213256",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://support.apple.com/kb/HT213255",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/tns-2022-09",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://security.netapp.com/advisory/ntap-20220429-0005/",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"name": "GLSA-202210-02",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://security.gentoo.org/glsa/202210-02"
|
|
},
|
|
{
|
|
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"x_adpType": "supplier",
|
|
"providerMetadata": {
|
|
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
|
|
"shortName": "siemens-SADP",
|
|
"dateUpdated": "2026-10-14T12:12:36.346Z"
|
|
},
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "BFCClient",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.17",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Industrial Edge - OPC UA Connector",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.7.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Industrial Edge - SIMATIC S7 Connector App",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.7.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "OpenPCS 7 V8.2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "OpenPCS 7 V9.0",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "OpenPCS 7 V9.1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM CROSSBOW Station Access Controller (SAC)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX MX5000",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX MX5000RE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1400",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1500",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1501",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1510",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1511",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1512",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1524",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX1536",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM ROX RX5000",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.15.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE LPE9403",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0 HF0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M804PB",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M812-1 ADSL-Router",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M812-1 ADSL-Router",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M816-1 ADSL-Router",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M816-1 ADSL-Router",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M826-2 SHDSL-Router",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M874-2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M874-3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M876-3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M876-3 (ROK)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M876-4",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M876-4 (EU)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE M876-4 (NAM)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE MUM853-1 (EU)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE MUM856-1 (EU)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE MUM856-1 (RoW)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE S615 EEC LAN-Router",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE S615 LAN-Router",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE SC622-2C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.3.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE SC632-2C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.3.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE SC636-2C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.3.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE SC642-2C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.3.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE SC646-2C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.3.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1748-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1748-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1750D (JP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V8.7.1.11",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1750D (ROW)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V8.7.1.11",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1750D (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V8.7.1.11",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1788-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1788-2 EEC M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1788-2 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W1788-2IA M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W721-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W721-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W721-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W721-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W722-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W722-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W722-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W722-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W722-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W722-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45 (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W734-1 RJ45 (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W738-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W738-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W738-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W738-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W748-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W761-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W761-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W761-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W761-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45 (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W774-1 RJ45 (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12 EEC (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W778-1 M12 EEC (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 SFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 SFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 SFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2 SFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2IA RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2IA RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2IA RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W786-2IA RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-1 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 M12 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE W788-2 RJ45",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WAM763-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WAM766-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WAM766-1 (US)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WAM766-1 EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WAM766-1 EEC (US)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WUM763-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WUM763-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WUM766-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE WUM766-1 (USA)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X200-4P IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X201-3P IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X201-3P IRT PRO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X202-2IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X202-2IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X202-2P IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X202-2P IRT PRO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204-2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204-2FM",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204-2LD",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204-2LD TS",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204-2TS",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X204IRT PRO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X206-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X206-1LD",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X208",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X208PRO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X212-2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X212-2LD",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X216",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X224",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (230V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (24V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (2x 230V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (2x 230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (2x 24V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X302-7 EEC (2x 24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X304-2FE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X306-1LD FE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (230V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (24V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (2x 230V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (2x 230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (2x 24V, coated)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-2 EEC (2x 24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-3LD",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X307-3LD",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2 RD (inkl. SIPLUS variants)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2LD",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2LD",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2LH",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2LH",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2LH+",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2LH+",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2M",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2M",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2M PoE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2M PoE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2M TS",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X308-2M TS",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X310",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X310",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X310FE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X310FE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X320-1 FE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X320-1-2LD FE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE X408-2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB205-3 (SC, PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB205-3 (ST, E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB205-3 (ST, E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB205-3 (ST, PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB205-3LD (SC, E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB205-3LD (SC, PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB208 (E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB208 (PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB213-3 (SC, E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB213-3 (SC, PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB213-3 (ST, E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB213-3 (ST, PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB213-3LD (SC, E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB213-3LD (SC, PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB216 (E/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XB216 (PN)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2 (SC)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2 (ST/BFOC)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2G PoE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2G PoE (54 V DC)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2SFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2SFP EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2SFP G",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC206-2SFP G EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC208",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC208EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC208G",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC208G (EIP def.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC208G EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC208G PoE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC208G PoE (54 V DC)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216-3G PoE",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216-3G PoE (54 V DC)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216-4C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216-4C G",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216-4C G (EIP Def.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216-4C G EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC216EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC224",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC224-4C G",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC224-4C G (EIP Def.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XC224-4C G EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF201-3P IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF202-2P IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204 DNA",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204-2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204-2BA",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204-2BA DNA",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204-2BA IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF204IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF206-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XF208",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XM408-4C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XM408-4C (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XM408-8C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XM408-8C (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XM416-4C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XM416-4C (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP208",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP208 (Ethernet/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP208EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP208PoE EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP216",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP216 (Ethernet/IP)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP216EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XP216POE EEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (230V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (230V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (230V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (230V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M (24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M TS (24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-12M TS (24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.1.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR326-2C PoE WG",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR326-2C PoE WG (without UL)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR524-8C, 1x230V",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR524-8C, 24V",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR524-8C, 2x230V",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR526-8C, 1x230V",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR526-8C, 24V",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR526-8C, 2x230V",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR528-6M",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR528-6M (2HR2)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR528-6M (L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR552-12M",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR552-12M (2HR2)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SCALANCE XR552-12M (2HR2)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V6.5.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Security Configuration Tool (SCT)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Cloud Connect 7 CC712",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.9.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Cloud Connect 7 CC716",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.9.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1242-7 V2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1243-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1243-7 LTE EU",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1243-7 LTE US",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1243-8 IRC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1542SP-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2.28",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1543-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.37",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1543SP-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2.28",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1545-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.1.80",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1626",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 1628",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 343-1 Advanced",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 443-1 Advanced",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3.11",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CP 443-1 OPC UA",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Drive Controller CPU 1504D TF",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Drive Controller CPU 1507D TF",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V21.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC HMI Unified Comfort Panels family",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V18.0 Update 0 SR0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Logon V1.6",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.6 Upd6",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC MV540 H",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC MV540 S",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC MV550 H",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC MV550 S",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC MV560 U",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC MV560 X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC NET PC Software V14",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC NET PC Software V15",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC NET PC Software V16",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V16 Update 6",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC NET PC Software V17",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V17 SP1 Update 1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC PCS 7 TeleControl",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V9.1 Update 1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC PCS 7 V8.2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC PCS 7 V9.0",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC PCS 7 V9.1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V9.1 SP2 UC04",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC PCS neo (Administration Console)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC PDM",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V9.2 SP2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Process Historian OPC UA Server",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2020 SP1 Update 1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF166C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF185C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF186C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF186CI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF188C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF188CI",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF360R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF610R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF615R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF650R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF680R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC RF685R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.0.1.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1211C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1211C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1211C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212FC DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214FC DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215FC DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1217C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V3.1.0",
|
|
"lessThan": "V3.1.5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V3.1.0",
|
|
"lessThan": "V3.1.5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V3.1.0",
|
|
"lessThan": "V3.1.5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V3.1.0",
|
|
"lessThan": "V3.1.5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 Software Controller V2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V21.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-PLCSIM Advanced",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 V15.1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 V16",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 V17",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V17 Update 5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 V5",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.7 HF4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC Unified (TIA Portal)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V17.0.0.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V15.1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V16",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V17",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V17 Update 5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V7.3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V7.4",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.4 SP1 Update 22",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V7.5",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V7.5 SP2 Update 16",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMOCODE ES V15.1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMOCODE ES V16",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMOCODE ES V17",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V17 Update 5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMOTION",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V5.1",
|
|
"lessThan": "V5.5.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMOTION SCOUT TIA V5.3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMOTION SCOUT TIA V5.4",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAMICS DCC V15.1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAMICS DCC V16",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAMICS Startdrive V15.1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAMICS Startdrive V16",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAMICS Startdrive V17",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAUT Software ST7sc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAUT ST7CC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINEC INS",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.0 SP2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINEC NMS",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.0 SP3",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINEMA Remote Connect Server",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2.28",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.2.28",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET CP 1242-7 V2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET CP 1543-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.37",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET CP 343-1 Advanced",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET CP 443-1 Advanced",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.3.11",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET SCALANCE X202-2P IRT",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.5.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET SCALANCE XC206-2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET SCALANCE XC206-2SFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET SCALANCE XC208",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS NET SCALANCE XC216-4C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.4",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CP 1243-1",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.4.29",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212C AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214FC DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215C AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.6.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.9.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V3.1.0",
|
|
"lessThan": "V3.1.5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.0.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS TIM 1531 IRC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.4.8",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIRIUS Safety ES V17 (TIA Portal)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V17 Update 5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIRIUS Soft Starter ES V15.1 (TIA Portal)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIRIUS Soft Starter ES V16 (TIA Portal)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V17 Update 5",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "TeleControl Server Basic V3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V3.1.1",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "TIA Administrator",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V1.0.8",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "TIA Portal Cloud V16",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "TIA Portal Cloud V17",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.3",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "TIM 1531 IRC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2.4.8",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-108696.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-028723.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-835",
|
|
"lang": "en",
|
|
"description": "CWE-835 Loop with Unreachable Exit Condition ('Infinite Loop')"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"scope": "UNCHANGED",
|
|
"version": "3.1",
|
|
"baseScore": 7.5,
|
|
"attackVector": "NETWORK",
|
|
"baseSeverity": "HIGH",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"integrityImpact": "NONE",
|
|
"userInteraction": "NONE",
|
|
"attackComplexity": "LOW",
|
|
"availabilityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"confidentialityImpact": "NONE"
|
|
}
|
|
},
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2026-05-22T13:27:14.476267Z",
|
|
"id": "CVE-2022-0778",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "yes"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2026-05-22T13:28:08.544Z"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"dataVersion": "5.2"
|
|
} |