"containers": {
|
||
"cna": {
|
||
"affected": [
|
||
{
|
||
"product": "Integrated Dell Remote Access Controller (iDRAC)",
|
||
"vendor": "Dell",
|
||
"versions": [
|
||
{
|
||
"lessThan": "4.32.10.00 and 4.40.00.00",
|
||
"status": "affected",
|
||
"version": "unspecified",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"datePublic": "2020-12-15T00:00:00.000Z",
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim’s browser by tricking a victim in to following a specially crafted link."
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV3_0": {
|
||
"attackComplexity": "LOW",
|
||
"attackVector": "NETWORK",
|
||
"availabilityImpact": "NONE",
|
||
"baseScore": 6.1,
|
||
"baseSeverity": "MEDIUM",
|
||
"confidentialityImpact": "LOW",
|
||
"integrityImpact": "LOW",
|
||
"privilegesRequired": "NONE",
|
||
"scope": "CHANGED",
|
||
"userInteraction": "REQUIRED",
|
||
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
|
||
"version": "3.0"
|
||
}
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-79",
|
||
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"dateUpdated": "2020-12-16T15:50:13.000Z",
|
||
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
|
||
"shortName": "dell"
|
||
},
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"x_refsource_MISC"
|
||
],
|
||
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
|
||
}
|
||
],
|
||
"x_legacyV4Record": {
|
||
"CVE_data_meta": {
|
||
"ASSIGNER": "secure@dell.com",
|
||
"DATE_PUBLIC": "2020-12-15",
|
||
"ID": "CVE-2020-26198",
|
||
"STATE": "PUBLIC"
|
||
},
|
||
"affects": {
|
||
"vendor": {
|
||
"vendor_data": [
|
||
{
|
||
"product": {
|
||
"product_data": [
|
||
{
|
||
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
|
||
"version": {
|
||
"version_data": [
|
||
{
|
||
"version_affected": "<",
|
||
"version_value": "4.32.10.00 and 4.40.00.00"
|
||
}
|
||
]
|
||
}
|
||
}
|
||
]
|
||
},
|
||
"vendor_name": "Dell"
|
||
}
|
||
]
|
||
}
|
||
},
|
||
"data_format": "MITRE",
|
||
"data_type": "CVE",
|
||
"data_version": "4.0",
|
||
"description": {
|
||
"description_data": [
|
||
{
|
||
"lang": "eng",
|
||
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim’s browser by tricking a victim in to following a specially crafted link."
|
||
}
|
||
]
|
||
},
|
||
"impact": {
|
||
"cvss": {
|
||
"baseScore": 6.1,
|
||
"baseSeverity": "Medium",
|
||
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
|
||
"version": "3.0"
|
||
}
|
||
},
|
||
"problemtype": {
|
||
"problemtype_data": [
|
||
{
|
||
"description": [
|
||
{
|
||
"lang": "eng",
|
||
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
|
||
}
|
||
]
|
||
}
|
||
]
|
||
},
|
||
"references": {
|
||
"reference_data": [
|
||
{
|
||
"name": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability",
|
||
"refsource": "MISC",
|
||
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
|
||
}
|
||
]
|
||
}
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"providerMetadata": {
|
||
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
||
"shortName": "CVE",
|
||
"dateUpdated": "2024-08-04T15:49:07.162Z"
|
||
},
|
||
"title": "CVE Program Container",
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"x_refsource_MISC",
|
||
"x_transferred"
|
||
],
|
||
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
|
||
}
|
||
]
|
||
}
|
||
]
|
||
},
|
||
"cveMetadata": {
|
||
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
|
||
"assignerShortName": "dell",
|
||
"cveId": "CVE-2020-26198",
|
||
"datePublished": "2020-12-16T15:50:13.965Z",
|
||
"dateReserved": "2020-09-30T00:00:00.000Z",
|
||
"dateUpdated": "2024-09-17T03:53:53.693Z",
|
||
"state": "PUBLISHED"
|
||
},
|
||
"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.1"
|
||
} |