1365 lines
64 KiB
JSON
1365 lines
64 KiB
JSON
{
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "C Controller Interface Module Utility",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 2.00",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "CC-Link IE Control Network Data Collector",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "Version 1.00A"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "CC-Link IE Field Network Data Collector",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "Version 1.00A"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "CC-Link IE TSN Data Collector",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "Version 1.00A"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "CPU Module Logging Configuration Tool",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.100E",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "CW Configurator",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.010L",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Data Transfer",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 3.42U",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "EZSocket",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 5.1",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "FR Configurator SW3",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All Versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "FR Configurator2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.26C",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT Designer2 Classic",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All Versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT Designer3 Version1 (GOT1000)",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.241B",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT Designer3 Version1 (GOT2000)",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.241B",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT SoftGOT1000 Version3",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 3.200J",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GT SoftGOT2000 Version1",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.241B",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GX Developer",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 8.504A",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GX LogViewer",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.100E",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GX Works2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.601B",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "GX Works3",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.063R",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "M_CommDTM-IO-Link",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.03D",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELFA-Works",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 4.4",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSEC WinCPU Setting Utility",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All Versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT Complete Clean Up Tool",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.06G",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT EM Software Development Kit",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.015R",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT iQ AppPortal",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.17T",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MELSOFT Navigator",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 2.74C",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MI Configurator",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.004E",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Motion Control Setting",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.005F",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Motorizer",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.005F",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MR Configurator2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.125F",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MT Works2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.167Z",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MTConnect Data Collector",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.1.4.0",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MX Component",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 4.20W",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MX MESInterface",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.21X",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MX MESInterface-R",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.12N",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "MX Sheet",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 2.15R",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Network Interface Board CC IE Control Utility",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.29F",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Network Interface Board CC IE Field Utility",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Versions 1.16S",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Network Interface Board CC-Link Ver.2 Utility",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.23Z",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Network Interface Board MNETH Utility",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 34L",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Position Board utility 2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 3.20",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "PX Developer",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.53F",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "RT ToolBox2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 3.73B",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "RT ToolBox3",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.82L",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Setting/Monitoring tools for the C Controller module",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "SW3PVC-CCPU Version 3.13P",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
},
|
|
{
|
|
"lessThanOrEqual": "SW4PVC-CCPU Version 4.12N",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "SLMP Data Collector",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.04E",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"type": "finder",
|
|
"user": "00000000-0000-4000-9000-000000000000",
|
|
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
|
|
}
|
|
],
|
|
"datePublic": "2020-07-30T06:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.\n\n<p></p>"
|
|
}
|
|
],
|
|
"value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.3,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-428",
|
|
"description": "CWE-428 Unquoted Search Path or Element",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"shortName": "icscert",
|
|
"dateUpdated": "2023-03-07T21:29:25.280Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"government-resource"
|
|
],
|
|
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
|
|
},
|
|
{
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "ICSA-20-212-04",
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"title": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
|
"DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
|
|
"ID": "CVE-2020-14521",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "C Controller Interface Module Utility",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "C Controller Module Setting and Monitoring Tool",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CC-Link IE Control Network Data Collector",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "Version 1.00A"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CC-Link IE Field Network Data Collector",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "Version 1.00A"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CC-Link IE TSN Data Collector",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "Version 1.00A"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CPU Module Logging Configuration Tool",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.100E"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CW Configurator",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.010L"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Data Transfer",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 3.42U and prior"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "EZSocket",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 5.1"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "FR Configurator SW3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "FR Configurator2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GT Designer2 Classic",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GT Designer3 Version1 (GOT1000)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.241B"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GT Designer3 Version1 (GOT2000)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.241B"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GT SoftGOT1000 Version3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 3.200J"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GT SoftGOT2000 Version1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.241B"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GX Developer",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 8.504A"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GX LogViewer",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.100E"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GX Works2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.601B"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GX Works3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.063R"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "M_CommDTM-IO-Link",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELFA-Works",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 4.4"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSEC WinCPU Setting Utility",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSOFT Complete Clean Up Tool",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.06G"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSOFT EM Software Development Kit",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSOFT iQ AppPortal",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.17T"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSOFT Navigator",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 2.74C"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MI Configurator",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Motion Control Setting",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.005F"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Motorizer",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.005F"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MR Configurator2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.125F"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MT Works2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.167Z"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MTConnect Data Collector",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.1.4.0"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MX Component",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 4.20W"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MX MESInterface",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.21X"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MX MESInterface-R",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.12N"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MX Sheet",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 2.15R"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Network Interface Board CC IE Control Utility",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Network Interface Board CC IE Field Utility",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Network Interface Board CC-Link Ver.2 Utility",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Network Interface Board MNETH Utility",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Position Board utility 2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "PX Developer",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "version 1.53F"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "RT ToolBox2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 3.73B"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "RT ToolBox3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.82L"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Setting/monitoring tools for the C Controller module",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SLMP Data Collector",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.04E"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Mitsubishi Electric"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"credit": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
|
|
}
|
|
],
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition."
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.3,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-428 Unquoted Search Path or Element"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04",
|
|
"refsource": "MISC",
|
|
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
|
|
},
|
|
{
|
|
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf",
|
|
"refsource": "MISC",
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "en"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "ICSA-20-212-04",
|
|
"discovery": "UNKNOWN"
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T12:46:34.835Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"government-resource",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
|
|
},
|
|
{
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-04-16T17:31:29.570752Z",
|
|
"id": "CVE-2020-14521",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-04-16T18:01:31.445Z"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"assignerShortName": "icscert",
|
|
"cveId": "CVE-2020-14521",
|
|
"datePublished": "2022-02-11T17:40:28.403Z",
|
|
"dateReserved": "2020-06-19T00:00:00.000Z",
|
|
"dateUpdated": "2025-04-16T18:01:31.445Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |