205 lines
9.0 KiB
JSON
205 lines
9.0 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2019-25719",
|
|
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "VulnCheck",
|
|
"dateReserved": "2026-06-02T13:54:01.021Z",
|
|
"datePublished": "2026-06-02T14:00:52.578Z",
|
|
"dateUpdated": "2026-06-03T15:43:03.688Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
|
|
"shortName": "VulnCheck",
|
|
"dateUpdated": "2026-06-03T15:43:03.688Z"
|
|
},
|
|
"title": "Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling",
|
|
"datePublic": "2019-09-12T00:00:00.000Z",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-924",
|
|
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Dräger",
|
|
"product": "Infinity Acute Care System",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThanOrEqual": "VG4.1.1",
|
|
"versionType": "custom"
|
|
},
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThanOrEqual": "VG4.0.3",
|
|
"versionType": "custom"
|
|
},
|
|
{
|
|
"status": "unaffected",
|
|
"version": "VG4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Dräger",
|
|
"product": "Standalone Infinity M540 patient monitor",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThanOrEqual": "VG4.1.1",
|
|
"versionType": "custom"
|
|
},
|
|
{
|
|
"status": "unaffected",
|
|
"version": "VG4.2",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attackers with access to an enabled Infinity network port or physical proximity to a wireless access point can modify device settings such as alarm states or alarm limits, and overwhelm the system with incoming data causing the device to reboot and lose network functionality.",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "<p>Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attackers with access to an enabled Infinity network port or physical proximity to a wireless access point can modify device settings such as alarm states or alarm limits, and overwhelm the system with incoming data causing the device to reboot and lose network functionality.</p>"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://static.draeger.com/security/download/PSA-19-255-02_Product-Security-Advisory-IACS-VG4.1.pdf",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.vulncheck.com/advisories/dr-ger-infinity-m540-vg4-spoofing-and-dos-via-network-message-handling",
|
|
"tags": [
|
|
"third-party-advisory"
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
],
|
|
"cvssV4_0": {
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"vulnConfidentialityImpact": "LOW",
|
|
"subConfidentialityImpact": "NONE",
|
|
"vulnIntegrityImpact": "LOW",
|
|
"subIntegrityImpact": "NONE",
|
|
"vulnAvailabilityImpact": "HIGH",
|
|
"subAvailabilityImpact": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"version": "4.0",
|
|
"baseSeverity": "HIGH",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N"
|
|
}
|
|
},
|
|
{
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
],
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "HIGH",
|
|
"baseSeverity": "HIGH",
|
|
"baseScore": 8.6,
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H"
|
|
}
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"x_generator": {
|
|
"engine": "Vulnogram 1.0.2"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2026-06-02T14:56:18.300929Z",
|
|
"id": "CVE-2019-25719",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "yes"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2026-06-02T14:56:35.870Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |