Files
vuln-cve/data/2024/4xxx/CVE-2024-4167.json
T

230 lines
8.9 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-4167",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"state": "PUBLISHED",
"assignerShortName": "VulDB",
"dateReserved": "2024-04-25T04:41:16.861Z",
"datePublished": "2024-04-25T12:00:05.316Z",
"dateUpdated": "2024-08-01T20:33:52.666Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2024-04-25T12:00:05.316Z"
},
"title": "Tenda 4G300 sub_422AA4 stack-based overflow",
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-121",
"lang": "en",
"description": "CWE-121 Stack-based Buffer Overflow"
}
]
}
],
"affected": [
{
"vendor": "Tenda",
"product": "4G300",
"versions": [
{
"version": "1.01.42",
"status": "affected"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda 4G300 1.01.42 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion sub_422AA4. Durch Beeinflussen des Arguments year/month/day/hour/minute/second mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden."
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"baseScore": 8.8,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
}
},
{
"cvssV3_0": {
"version": "3.0",
"baseScore": 8.8,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
}
},
{
"cvssV2_0": {
"version": "2.0",
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"
}
}
],
"timeline": [
{
"time": "2024-04-25T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2024-04-25T02:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2024-04-25T06:46:29.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "wxhwxhwxh_mie (VulDB User)",
"type": "reporter"
}
],
"references": [
{
"url": "https://vuldb.com/?id.261986",
"name": "VDB-261986 | Tenda 4G300 sub_422AA4 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
]
},
{
"url": "https://vuldb.com/?ctiid.261986",
"name": "VDB-261986 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/?submit.318983",
"name": "Submit #318983 | Tenda 4G300 V1.01.42 Buffer Overflow",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_422AA4.md",
"tags": [
"related"
]
}
]
},
"adp": [
{
"title": "CISA ADP Vulnrichment",
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"id": "CVE-2024-4167",
"role": "CISA Coordinator",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-02T17:32:59.611346Z"
}
}
}
],
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "4g300",
"versions": [
{
"status": "affected",
"version": "-"
}
],
"defaultStatus": "unknown"
}
],
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-04T17:53:19.796Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-01T20:33:52.666Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://vuldb.com/?id.261986",
"name": "VDB-261986 | Tenda 4G300 sub_422AA4 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
]
},
{
"url": "https://vuldb.com/?ctiid.261986",
"name": "VDB-261986 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
]
},
{
"url": "https://vuldb.com/?submit.318983",
"name": "Submit #318983 | Tenda 4G300 V1.01.42 Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
]
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_422AA4.md",
"tags": [
"related",
"x_transferred"
]
}
]
}
]
}
}