"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "Simcenter Femap V2020.2",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Simcenter Femap V2021.1",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602)"
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-121",
|
|
"description": "CWE-121: Stack-based Buffer Overflow",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-02-11T18:07:07.000Z",
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-311/"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-312/"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-313/"
|
|
}
|
|
],
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"ID": "CVE-2021-46158",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Simcenter Femap V2020.2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Simcenter Femap V2021.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Siemens"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602)"
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-121: Stack-based Buffer Overflow"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf",
|
|
"refsource": "MISC",
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf"
|
|
},
|
|
{
|
|
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-311/",
|
|
"refsource": "MISC",
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-311/"
|
|
},
|
|
{
|
|
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-312/",
|
|
"refsource": "MISC",
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-312/"
|
|
},
|
|
{
|
|
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-313/",
|
|
"refsource": "MISC",
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-313/"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T05:02:10.856Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-311/"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-312/"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-313/"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"assignerShortName": "siemens",
|
|
"cveId": "CVE-2021-46158",
|
|
"datePublished": "2022-02-09T15:17:23.000Z",
|
|
"dateReserved": "2022-01-07T00:00:00.000Z",
|
|
"dateUpdated": "2024-08-04T05:02:10.856Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |