Files
vuln-cve/data/2021/45xxx/CVE-2021-45971.json
T

428 lines
17 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"containers": {
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (CommBufferData)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:45.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-45971",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SdHostDriver in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (CommBufferData)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0004/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
},
"adp": [
{
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0004/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2025-11-04T19:12:49.634Z"
}
},
{
"x_adpType": "supplier",
"providerMetadata": {
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP",
"dateUpdated": "2026-08-11T12:22:26.567Z"
},
"affected": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM APE1808 - BIOS",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V1.0.202N",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC Field PG M5",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V22.01.10",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC Field PG M6",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V26.01.13",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC127E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V27.01.09",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC227G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC277G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC277G PRO",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC327G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC377G",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V28.01.04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC427E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC477E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC477E PRO",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC627E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC647E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC677E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC847E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V25.02.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ITP1000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V23.01.10",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS IPC427E",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V21.01.17",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-45971",
"datePublished": "2022-01-05T23:09:47.000Z",
"dateReserved": "2022-01-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:26.567Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}