"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "CP-8000 MASTER MODULE WITH I/O -25/+70°C",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V16.20"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "CP-8000 MASTER MODULE WITH I/O -40/+70°C",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V16.20"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "CP-8021 MASTER MODULE",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V16.20"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "CP-8022 MASTER MODULE WITH GPRS",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V16.20"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links."
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-284",
|
|
"description": "CWE-284: Improper Access Control",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-04-15T17:06:20.000Z",
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
|
|
},
|
|
{
|
|
"name": "20220414 SEC Consult SA-20220413 :: Missing Authentication at File Download & Denial of Service in Siemens A8000 PLC",
|
|
"tags": [
|
|
"mailing-list",
|
|
"x_refsource_FULLDISC"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/Apr/20"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html"
|
|
}
|
|
],
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"ID": "CVE-2021-45034",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "CP-8000 MASTER MODULE WITH I/O -25/+70°C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V16.20"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CP-8000 MASTER MODULE WITH I/O -40/+70°C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V16.20"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CP-8021 MASTER MODULE",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V16.20"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "CP-8022 MASTER MODULE WITH GPRS",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V16.20"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Siemens"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-284: Improper Access Control"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf",
|
|
"refsource": "MISC",
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
|
|
},
|
|
{
|
|
"name": "20220414 SEC Consult SA-20220413 :: Missing Authentication at File Download & Denial of Service in Siemens A8000 PLC",
|
|
"refsource": "FULLDISC",
|
|
"url": "http://seclists.org/fulldisclosure/2022/Apr/20"
|
|
},
|
|
{
|
|
"name": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html",
|
|
"refsource": "MISC",
|
|
"url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T04:32:13.633Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
|
|
},
|
|
{
|
|
"name": "20220414 SEC Consult SA-20220413 :: Missing Authentication at File Download & Denial of Service in Siemens A8000 PLC",
|
|
"tags": [
|
|
"mailing-list",
|
|
"x_refsource_FULLDISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://seclists.org/fulldisclosure/2022/Apr/20"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"assignerShortName": "siemens",
|
|
"cveId": "CVE-2021-45034",
|
|
"datePublished": "2022-01-11T11:27:17.000Z",
|
|
"dateReserved": "2021-12-13T00:00:00.000Z",
|
|
"dateUpdated": "2024-08-04T04:32:13.633Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |