"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"state": "PUBLISHED",
|
|
"cveId": "CVE-2021-43336",
|
|
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"assignerShortName": "mitre",
|
|
"dateUpdated": "2024-08-04T03:55:28.546Z",
|
|
"dateReserved": "2021-11-03T00:00:00.000Z",
|
|
"datePublished": "2021-11-14T00:00:00.000Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"shortName": "mitre",
|
|
"dateUpdated": "2023-02-14T00:00:00.000Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "n/a",
|
|
"product": "n/a",
|
|
"versions": [
|
|
{
|
|
"version": "n/a",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.opendesign.com/security-advisories"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
|
|
},
|
|
{
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "text",
|
|
"lang": "en",
|
|
"description": "n/a"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T03:55:28.546Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://www.opendesign.com/security-advisories",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-334/",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |