Files
vuln-cve/data/2021/38xxx/CVE-2021-38404.json
T

252 lines
10 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"containers": {
"cna": {
"affected": [
{
"product": "DOPSoft 2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "2.00.07",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "kimiya, working with Trend Micro’s Zero Day Initiative"
}
],
"datePublic": "2021-09-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-17T18:54:45.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
}
],
"solutions": [
{
"lang": "en",
"value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
}
],
"source": {
"advisory": "ICSA-21-252-02",
"discovery": "UNKNOWN"
},
"title": "Delta Electronics DOPSoft 2 Heap-based Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-09-09T14:34:00.000Z",
"ID": "CVE-2021-38404",
"STATE": "PUBLIC",
"TITLE": "Delta Electronics DOPSoft 2 Heap-based Buffer Overflow"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DOPSoft 2",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_value": "2.00.07"
}
]
}
}
]
},
"vendor_name": "Delta Electronics"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "kimiya, working with Trend Micro’s Zero Day Initiative"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122 Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
}
]
},
"solution": [
{
"lang": "en",
"value": "DOPSoft 2 will not receive an update to mitigate these vulnerabilities because it is an end-of-life product. Delta Electronics recommends users to switch to the replacement software when available"
}
],
"source": {
"advisory": "ICSA-21-252-02",
"discovery": "UNKNOWN"
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-04T01:37:16.563Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-02"
}
]
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-04-23T13:16:40.921801Z",
"id": "CVE-2021-38404",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-04-23T19:27:36.639Z"
}
}
]
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38404",
"datePublished": "2021-09-17T18:54:45.055Z",
"dateReserved": "2021-08-10T00:00:00.000Z",
"dateUpdated": "2025-04-23T19:27:36.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}