Files
vuln-cve/data/2021/34xxx/CVE-2021-34598.json
T

254 lines
11 KiB
JSON

{
"containers": {
"cna": {
"affected": [
{
"product": "FL MGUARD",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "FL MGUARD 1102 (No. 1153079)*",
"status": "affected",
"version": "1.4.0",
"versionType": "custom"
},
{
"lessThan": "FL MGUARD 1105 (No. 1153078)*",
"status": "affected",
"version": "1.4.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This vulnerability was discovered by a key customer. We kindly appreciate the coordinated disclosure of this vulnerability by the finder."
}
],
"datePublic": "2021-11-10T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In Phoenix Contact FL MGUARD 1102 and 1105 in Versions 1.4.0, 1.4.1 and 1.5.0 the remote logging functionality is impaired by the lack of memory release for data structures from syslog-ng when remote logging is active"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-401",
"description": "CWE-401 Improper Release of Memory Before Removing Last Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-10T11:22:05.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-046/"
}
],
"solutions": [
{
"lang": "en",
"value": "PHOENIX CONTACT recomments to upgrade to firmware version 1.5.1 (or any later version)."
}
],
"source": {
"advisory": "VDE-2021-046",
"discovery": "EXTERNAL"
},
"title": "Phoenix Contact: FL MGUARD lack of memory release in remote logging functionality",
"workarounds": [
{
"lang": "en",
"value": "To prevent the possibility of an attack, it is recommended to deactivate remote logging."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-11-10T11:00:00.000Z",
"ID": "CVE-2021-34598",
"STATE": "PUBLIC",
"TITLE": "Phoenix Contact: FL MGUARD lack of memory release in remote logging functionality"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FL MGUARD",
"version": {
"version_data": [
{
"version_affected": ">=",
"version_name": "FL MGUARD 1102 (No. 1153079)",
"version_value": "1.4.0"
},
{
"version_affected": "<=",
"version_name": "FL MGUARD 1102 (No. 1153079)",
"version_value": "1.5.0 +1"
},
{
"version_affected": ">=",
"version_name": "FL MGUARD 1105 (No. 1153078)",
"version_value": "1.4.0"
},
{
"version_affected": "<=",
"version_name": "FL MGUARD 1105 (No. 1153078)",
"version_value": "1.5.0 +1"
}
]
}
}
]
},
"vendor_name": "PHOENIX CONTACT"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This vulnerability was discovered by a key customer. We kindly appreciate the coordinated disclosure of this vulnerability by the finder."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Phoenix Contact FL MGUARD 1102 and 1105 in Versions 1.4.0, 1.4.1 and 1.5.0 the remote logging functionality is impaired by the lack of memory release for data structures from syslog-ng when remote logging is active"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-401 Improper Release of Memory Before Removing Last Reference"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2021-046/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2021-046/"
}
]
},
"solution": [
{
"lang": "en",
"value": "PHOENIX CONTACT recomments to upgrade to firmware version 1.5.1 (or any later version)."
}
],
"source": {
"advisory": "VDE-2021-046",
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "To prevent the possibility of an attack, it is recommended to deactivate remote logging."
}
]
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-04T00:19:47.409Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-046/"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34598",
"datePublished": "2021-11-10T11:22:05.667Z",
"dateReserved": "2021-06-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:39:35.785Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}