192 lines
7.9 KiB
JSON
192 lines
7.9 KiB
JSON
{
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"platforms": [
|
|
"CPP4, CPP6, CPP7, CPP7.3"
|
|
],
|
|
"product": "CPP Firmware",
|
|
"vendor": "Bosch",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"datePublic": "2021-05-20T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A specially crafted TCP/IP packet may cause a camera recovery image telnet interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "PHYSICAL",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.8,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-121",
|
|
"description": "CWE-121 Stack-based Buffer Overflow",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-03-30T16:03:03.000Z",
|
|
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"shortName": "bosch"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM"
|
|
],
|
|
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "BOSCH-SA-478243-BT",
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"title": "Buffer Overflow vulnerability in the recovery image telnet server",
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "psirt@bosch.com",
|
|
"DATE_PUBLIC": "2021-05-20",
|
|
"ID": "CVE-2021-23850",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "Buffer Overflow vulnerability in the recovery image telnet server"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "CPP Firmware",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"platform": "CPP4, CPP6, CPP7, CPP7.3",
|
|
"version_affected": "=",
|
|
"version_value": "all"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Bosch"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A specially crafted TCP/IP packet may cause a camera recovery image telnet interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware."
|
|
}
|
|
]
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "PHYSICAL",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.8,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-121 Stack-based Buffer Overflow"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
|
|
"refsource": "CONFIRM",
|
|
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
|
|
}
|
|
]
|
|
},
|
|
"source": {
|
|
"advisory": "BOSCH-SA-478243-BT",
|
|
"discovery": "UNKNOWN"
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-03T19:14:09.385Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"assignerShortName": "bosch",
|
|
"cveId": "CVE-2021-23850",
|
|
"datePublished": "2022-03-30T16:03:03.708Z",
|
|
"dateReserved": "2021-01-12T00:00:00.000Z",
|
|
"dateUpdated": "2024-09-17T02:57:11.806Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |