236 lines
9.9 KiB
JSON
236 lines
9.9 KiB
JSON
{
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "B426 Firmware",
|
|
"vendor": "Bosch",
|
|
"versions": [
|
|
{
|
|
"lessThan": "03.08",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "B426-CN/B429- CN Firmware",
|
|
"vendor": "Bosch",
|
|
"versions": [
|
|
{
|
|
"lessThan": "03.08",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "B426-M Firmware",
|
|
"vendor": "Bosch",
|
|
"versions": [
|
|
{
|
|
"lessThan": "03.10",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"datePublic": "2021-05-28T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "This vulnerability could allow an attacker to hijack a session while a user is logged in the configuration web page. This vulnerability was discovered by a security researcher in B426 and found during internal product tests in B426-CN/B429-CN, and B426-M and has been fixed already starting from version 3.08 on, which was released on June 2019."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-284",
|
|
"description": "CWE-284 Improper Access Control",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2021-06-18T13:38:31.000Z",
|
|
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"shortName": "bosch"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM"
|
|
],
|
|
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "BOSCH-SA-196933-BT",
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"title": "B426 Web Configuration Authentication Bypass",
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "psirt@bosch.com",
|
|
"DATE_PUBLIC": "2021-05-28",
|
|
"ID": "CVE-2021-23845",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "B426 Web Configuration Authentication Bypass"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "B426 Firmware",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_value": "03.08"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "B426-CN/B429- CN Firmware",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_value": "03.08"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "B426-M Firmware",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_value": "03.10"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Bosch"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "This vulnerability could allow an attacker to hijack a session while a user is logged in the configuration web page. This vulnerability was discovered by a security researcher in B426 and found during internal product tests in B426-CN/B429-CN, and B426-M and has been fixed already starting from version 3.08 on, which was released on June 2019."
|
|
}
|
|
]
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-284 Improper Access Control"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html",
|
|
"refsource": "CONFIRM",
|
|
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
|
|
}
|
|
]
|
|
},
|
|
"source": {
|
|
"advisory": "BOSCH-SA-196933-BT",
|
|
"discovery": "UNKNOWN"
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-03T19:14:09.174Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"assignerShortName": "bosch",
|
|
"cveId": "CVE-2021-23845",
|
|
"datePublished": "2021-06-18T13:38:31.304Z",
|
|
"dateReserved": "2021-01-12T00:00:00.000Z",
|
|
"dateUpdated": "2024-09-16T21:57:38.685Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |