Files
vuln-cve/data/2021/23xxx/CVE-2021-23281.json
T

239 lines
10 KiB
JSON

{
"containers": {
"cna": {
"affected": [
{
"product": "Intelligent Power manager (IPM)",
"vendor": "Eaton",
"versions": [
{
"lessThan": "1.69",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Amir Preminger from Claroty research"
}
],
"datePublic": "2021-04-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code ('Code Injection')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-13T18:03:54.000Z",
"orgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759",
"shortName": "Eaton"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "upgrade the software to latest version 1.69"
}
],
"source": {
"advisory": "ETN-VA-2021-1000",
"defect": [
"ETN-VA-2021-1000"
],
"discovery": "EXTERNAL"
},
"title": "Remote Code execution",
"workarounds": [
{
"lang": "en",
"value": "To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 & 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "Code Injection",
"ASSIGNER": "CybersecurityCOE@eaton.com",
"DATE_PUBLIC": "2021-04-01T07:00:00.000Z",
"ID": "CVE-2021-23281",
"STATE": "PUBLIC",
"TITLE": "Remote Code execution"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intelligent Power manager (IPM)",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "1.69"
}
]
}
}
]
},
"vendor_name": "Eaton"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Amir Preminger from Claroty research"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-94 Improper Control of Generation of Code ('Code Injection')"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf",
"refsource": "MISC",
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "upgrade the software to latest version 1.69"
}
],
"source": {
"advisory": "ETN-VA-2021-1000",
"defect": [
"ETN-VA-2021-1000"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 & 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"
}
]
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T19:05:55.648Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759",
"assignerShortName": "Eaton",
"cveId": "CVE-2021-23281",
"datePublished": "2021-04-13T18:03:54.932Z",
"dateReserved": "2021-01-08T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:41:57.724Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}