"affected": [
{
"product": "PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-11T15:40:47.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
}
],
"tags": [
"unsupported-when-assigned"
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22767",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)",
"version": {
"version_data": [
{
"version_value": "PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22768"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03",
"refsource": "MISC",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
}
]
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T18:51:07.595Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
}
]
},
{
"metrics": [
{
"cvssV3_1": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
}
},
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-05-29T13:46:57.905052Z",
"id": "CVE-2021-22767",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-05-29T13:47:16.557Z"
}
}
]
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22767",
"datePublished": "2021-06-11T15:40:47.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:47:16.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}