"containers": {
"cna": {
"affected": [
{
"product": "800xA, Control Software for AC 800M OPC Server for AC 800M",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "5.1.0-x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "5.1.1-x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"status": "affected",
"version": "6.0.0-1"
},
{
"status": "affected",
"version": "6.0.0-2"
},
{
"status": "affected",
"version": "6.0.0-3"
}
]
},
{
"product": "Control Builder Safe, version 1.x OPC Server for AC 800M",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "5.1.1-1"
}
]
},
{
"product": "Control Builder Safe, version 2.0 OPC Server for AC 800M",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "6.0.0-1"
}
]
},
{
"product": "Compact Product Suite - Control and I/O OPC Server for AC 800M",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "5.1.0-x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "5.1.1-x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "6.0.0-x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "ABB thanks William Knowles at Applied Risk for helping to identify the vulnerabilities and protecting our customers."
}
],
"datePublic": "2022-01-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-04T22:29:21.000Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA000908&LanguageCode=en&DocumentPartId=&Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"value": "Customers on version 5.1 or older are recommended to upgrade to a supported version that is not affected by this issue such as version 6.1 or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SECURITY - OPC Server for AC 800M - Remote Code Execution Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"DATE_PUBLIC": "2022-01-24T11:58:00.000Z",
"ID": "CVE-2021-22284",
"STATE": "PUBLIC",
"TITLE": "SECURITY - OPC Server for AC 800M - Remote Code Execution Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "800xA, Control Software for AC 800M OPC Server for AC 800M",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_value": "5.1.0-x"
},
{
"version_affected": "<=",
"version_value": "5.1.1-x"
},
{
"version_affected": "=",
"version_value": "6.0.0-1"
},
{
"version_affected": "=",
"version_value": "6.0.0-2"
},
{
"version_affected": "=",
"version_value": "6.0.0-3"
}
]
}
},
{
"product_name": "Control Builder Safe, version 1.x OPC Server for AC 800M",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.1-1"
}
]
}
},
{
"product_name": "Control Builder Safe, version 2.0 OPC Server for AC 800M",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "6.0.0-1"
}
]
}
},
{
"product_name": "Compact Product Suite - Control and I/O OPC Server for AC 800M",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_value": "5.1.0-x"
},
{
"version_affected": "<=",
"version_value": "5.1.1-x"
},
{
"version_affected": "<=",
"version_value": "6.0.0-x"
}
]
}
}
]
},
"vendor_name": "ABB"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "ABB thanks William Knowles at Applied Risk for helping to identify the vulnerabilities and protecting our customers."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA000908&LanguageCode=en&DocumentPartId=&Action=Launch",
"refsource": "MISC",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA000908&LanguageCode=en&DocumentPartId=&Action=Launch"
}
]
},
"solution": [
{
"lang": "en",
"value": "Customers on version 5.1 or older are recommended to upgrade to a supported version that is not affected by this issue such as version 6.1 or later."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T18:37:18.516Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA000908&LanguageCode=en&DocumentPartId=&Action=Launch"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2021-22284",
"datePublished": "2022-02-04T22:29:21.143Z",
"dateReserved": "2021-01-05T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:56:36.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}