180 lines
8.0 KiB
JSON
180 lines
8.0 KiB
JSON
{
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "n/a",
|
|
"vendor": "n/a",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "n/a"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"datePublic": "2017-08-05T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the inverter is compromised completely. This allows the attacker to do nearly anything: for example, giving access to the local OS, creating a botnet, using the inverters as a stepping stone into companies, etc. NOTE: the vendor reports that this attack has always been blocked by \"a final integrity and compatibility check.\" Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected"
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"description": "n/a",
|
|
"lang": "en",
|
|
"type": "text"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2017-08-21T08:57:01.000Z",
|
|
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"shortName": "mitre"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "http://www.sma.de/en/statement-on-cyber-security.html"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://horusscenario.com/CVE-information/"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf"
|
|
}
|
|
],
|
|
"tags": [
|
|
"disputed"
|
|
],
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "cve@mitre.org",
|
|
"ID": "CVE-2017-9860",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "n/a",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "n/a"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "n/a"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "** DISPUTED ** An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the inverter is compromised completely. This allows the attacker to do nearly anything: for example, giving access to the local OS, creating a botnet, using the inverters as a stepping stone into companies, etc. NOTE: the vendor reports that this attack has always been blocked by \"a final integrity and compatibility check.\" Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "n/a"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "http://www.sma.de/en/statement-on-cyber-security.html",
|
|
"refsource": "MISC",
|
|
"url": "http://www.sma.de/en/statement-on-cyber-security.html"
|
|
},
|
|
{
|
|
"name": "https://horusscenario.com/CVE-information/",
|
|
"refsource": "MISC",
|
|
"url": "https://horusscenario.com/CVE-information/"
|
|
},
|
|
{
|
|
"name": "http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf",
|
|
"refsource": "MISC",
|
|
"url": "http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-05T17:18:01.930Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://www.sma.de/en/statement-on-cyber-security.html"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://horusscenario.com/CVE-information/"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
|
|
"assignerShortName": "mitre",
|
|
"cveId": "CVE-2017-9860",
|
|
"datePublished": "2017-08-05T17:00:00.000Z",
|
|
"dateReserved": "2017-06-24T00:00:00.000Z",
|
|
"dateUpdated": "2024-08-05T17:18:01.930Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |