Files
vuln-cve/data/2017/18xxx/CVE-2017-18834.json
T

172 lines
7.1 KiB
JSON

{
"containers": {
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by reflected XSS. This affects M4300-28G before 12.0.2.15, M4300-52G before 12.0.2.15, M4300-28G-POE+ before 12.0.2.15, M4300-52G-POE+ before 12.0.2.15, M4300-8X8F before 12.0.2.15, M4300-12X12F before 12.0.2.15, M4300-24X24F before 12.0.2.15, M4300-24X before 12.0.2.15, M4300-48X before 12.0.2.15, and M4200 before 12.0.2.15."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AC:L/AV:L/A:L/C:L/I:L/PR:N/S:C/UI:R",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-20T16:24:42.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000049028/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Fully-Managed-Switches-PSV-2017-1956"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-18834",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by reflected XSS. This affects M4300-28G before 12.0.2.15, M4300-52G before 12.0.2.15, M4300-28G-POE+ before 12.0.2.15, M4300-52G-POE+ before 12.0.2.15, M4300-8X8F before 12.0.2.15, M4300-12X12F before 12.0.2.15, M4300-24X24F before 12.0.2.15, M4300-24X before 12.0.2.15, M4300-48X before 12.0.2.15, and M4200 before 12.0.2.15."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AC:L/AV:L/A:L/C:L/I:L/PR:N/S:C/UI:R",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000049028/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Fully-Managed-Switches-PSV-2017-1956",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000049028/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Fully-Managed-Switches-PSV-2017-1956"
}
]
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-05T21:37:44.256Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000049028/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Fully-Managed-Switches-PSV-2017-1956"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-18834",
"datePublished": "2020-04-20T16:24:42.000Z",
"dateReserved": "2020-04-20T00:00:00.000Z",
"dateUpdated": "2024-08-05T21:37:44.256Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}